<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>MCB's - Electrogear Ltd</title>
	<atom:link href="https://electrogear.co.uk/product-category/circuit-protection/mcbs/feed/" rel="self" type="application/rss+xml" />
	<link>https://electrogear.co.uk</link>
	<description>Specialist Distributors to Water Industry and the Electrical Trade</description>
	<lastBuildDate>Sat, 02 Nov 2024 10:22:15 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://electrogear.co.uk/wp-content/uploads/2024/04/cropped-electrogear-logo-512-32x32.png</url>
	<title>MCB's - Electrogear Ltd</title>
	<link>https://electrogear.co.uk</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Schneider Acti9 3P D Curve 63A</title>
		<link>https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-63a/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=schneider-acti9-3p-d-curve-63a</link>
		
		<dc:creator><![CDATA[electrogear-user]]></dc:creator>
		<pubDate>Tue, 24 Aug 2021 15:06:57 +0000</pubDate>
				<guid isPermaLink="false">https://electrogear.co.uk/?post_type=product&#038;p=24561</guid>

					<description><![CDATA[<p>A9F85363</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-63a/">Schneider Acti9 3P D Curve 63A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></description>
										<content:encoded><![CDATA[<div     class="vc_row wpb_row section vc_row-fluid " style=' padding-bottom:50px; text-align:left;'><div class=" full_section_inner clearfix"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div id="lvca-tabs-6a52a0e6e8a43" class="lvca-tabs lvca-vertical lvca-style8" data-mobile-width="600"><a href="#" class="lvca-tab-mobile-menu"><i class="lvca-icon-menu"></i>&nbsp;</a><div class="lvca-tab-nav"><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">OVERVIEW</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">DETAILS</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">MORE INFORMATION</span></a></div></div><div class="lvca-tab-panes"><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<h3 data-testid="descriptive-content-main-header"><b>Schneider Electric | Acti9 iC60H | Mini Circuit Breakers</b></h3>
<p>&nbsp;</p>
<p>The Acti9 series of MCBs by Schneider Electric provides excellent circuit protection particularly in combating short circuits and overload currents. These MCBs are rigorously tested by Schneider and are compliant with standards such as IEC/EN 60898 &amp; 60947-2. These types of MCBs are typically used in industrial or commercial buildings and can work extremely well in polluted environments.</p>
<p>&nbsp;</p>
<h3 data-testid="descriptive-content-main-header"><b>Features and benefits:</b></h3>
<p>&nbsp;</p>
<p>• Easy to install these consumer units, single clip on to Din Rail, compact in nature making wiring easier and simplifying your circuit system. Ergonomically designed with robust connections. IP20B terminal shutters.</p>
<p>• Schneider &#8216;VisiSafe&#8217; for safer operation and maintenance work on electrical circuits. Absolute safety of circuit protection guaranteed.</p>
<p>• Schneider &#8216;VisiTrip&#8217; for easier fault detection in the MCB outgoers. This can help reduce intervention time greatly, protecting the device before any further electrical problems occur.</div><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<table class="pes-table">
<tbody>
<tr>
<th class="pes-text-left char-table__title">Device application</th>
<td class="pes-text-left">
<div>Distribution</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">range</th>
<td class="pes-text-left">
<div>Acti 9</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">product name</th>
<td class="pes-text-left">
<div>Acti 9 iC60</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Product or component type</th>
<td class="pes-text-left">
<div>Miniature circuit-breaker</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">device short name</th>
<td class="pes-text-left">
<div>IC60H</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">poles description</th>
<td class="pes-text-left">
<div>3P</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">number of protected poles</th>
<td class="pes-text-left">
<div>3</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[In] rated current</th>
<td class="pes-text-left">
<div>63 A</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">network type</th>
<td class="pes-text-left">
<div>AC<br />
DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">trip unit technology</th>
<td class="pes-text-left">
<div>Thermal-magnetic</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">curve code</th>
<td class="pes-text-left">
<div>D</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">breaking capacity</th>
<td class="pes-text-left">
<div>10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1<br />
42 kA Icu at 12&#8230;60 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at 380&#8230;415 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
30 kA Icu at 220&#8230;240 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
42 kA Icu at 100&#8230;133 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at &lt;= 180 V DC conforming to EN/IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">utilisation category</th>
<td class="pes-text-left">
<div>Category A conforming to EN 60947-2<br />
Category A conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">suitability for isolation</th>
<td class="pes-text-left">
<div>Yes conforming to EN 60898-1<br />
Yes conforming to EN 60947-2<br />
Yes conforming to IEC 60898-1<br />
Yes conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">standards</th>
<td class="pes-text-left">
<div>IEC 60898-1<br />
IEC 60947-2<br />
EN 60947-2<br />
EN 60898-1</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Complementary</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Network frequency</th>
<td class="pes-text-left">
<div>50/60 Hz</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">magnetic tripping limit</th>
<td class="pes-text-left">
<div>12 x In +/- 20 %</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ics] rated service breaking capacity</th>
<td class="pes-text-left">
<div>15 kA 50 % conforming to EN 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to EN 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to EN 60947-2 &#8211; 440 V AC 50/60 Hz<br />
15 kA 50 % conforming to IEC 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to IEC 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to IEC 60947-2 &#8211; 440 V AC 50/60 Hz<br />
7500 A 75 % conforming to EN 60898-1 &#8211; 400 V AC 50/60 Hz<br />
7500 A 75 % conforming to IEC 60898-1 &#8211; 400 V AC 50/60 Hz<br />
21 kA 50 % conforming to IEC 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
21 kA 50 % conforming to EN 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
15 kA 100 % conforming to IEC 60947-2 &#8211; 125&#8230;180 V DC<br />
15 kA 100 % conforming to EN 60947-2 &#8211; 125&#8230;180 V DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">limitation class</th>
<td class="pes-text-left">
<div>3 conforming to EN 60898-1<br />
3 conforming to IEC 60898-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ui] rated insulation voltage</th>
<td class="pes-text-left">
<div>500 V AC 50/60 Hz conforming to EN 60947-2<br />
500 V AC 50/60 Hz conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Uimp] rated impulse withstand voltage</th>
<td class="pes-text-left">
<div>6 kV conforming to EN 60947-2<br />
6 kV conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">contact position indicator</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Control type</th>
<td class="pes-text-left">
<div>Toggle</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">local signalling</th>
<td class="pes-text-left">
<div>Trip indicator</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting mode</th>
<td class="pes-text-left">
<div>Fixed</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting support</th>
<td class="pes-text-left">
<div>DIN rail</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">comb busbar and distribution block compatibility</th>
<td class="pes-text-left">
<div>Top or bottom: YES</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">9 mm pitches</th>
<td class="pes-text-left">
<div>6</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Height</th>
<td class="pes-text-left">
<div>85 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Width</th>
<td class="pes-text-left">
<div>54 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Depth</th>
<td class="pes-text-left">
<div>78.5 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Net weight</th>
<td class="pes-text-left">
<div>0.375 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">colour</th>
<td class="pes-text-left">
<div>White</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">mechanical durability</th>
<td class="pes-text-left">
<div>20000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">electrical durability</th>
<td class="pes-text-left">
<div>10000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">connections &#8211; terminals</th>
<td class="pes-text-left">
<div>Single terminal (top or bottom) 1…35 mm² rigid<br />
Single terminal (top or bottom) 1…25 mm² flexible</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">wire stripping length</th>
<td class="pes-text-left">
<div>14 mm for top or bottom connection</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tightening torque</th>
<td class="pes-text-left">
<div>3.5 N.m top or bottom</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">earth-leakage protection</th>
<td class="pes-text-left">
<div>Separate block</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Environment</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">IP degree of protection</th>
<td class="pes-text-left">
<div>IP20 conforming to IEC 60529<br />
IP20 conforming to EN 60529</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">pollution degree</th>
<td class="pes-text-left">
<div>3 conforming to EN 60947-2<br />
3 conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">overvoltage category</th>
<td class="pes-text-left">
<div>IV</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tropicalisation</th>
<td class="pes-text-left">
<div>2 conforming to IEC 60068-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">relative humidity</th>
<td class="pes-text-left">
<div>95 % at 55 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">operating altitude</th>
<td class="pes-text-left">
<div>0&#8230;2000 m</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for operation</th>
<td class="pes-text-left">
<div>-35…70 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for storage</th>
<td class="pes-text-left">
<div>-40…85 °C</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Packing Units</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 1</th>
<td class="pes-text-left">
<div>PCE</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 1</th>
<td class="pes-text-left">
<div>1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Weight</th>
<td class="pes-text-left">
<div>402.25 g</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Height</th>
<td class="pes-text-left">
<div>5.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 width</th>
<td class="pes-text-left">
<div>7.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Length</th>
<td class="pes-text-left">
<div>9.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 2</th>
<td class="pes-text-left">
<div>BB1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 2</th>
<td class="pes-text-left">
<div>4</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Weight</th>
<td class="pes-text-left">
<div>1.672 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Height</th>
<td class="pes-text-left">
<div>8 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 width</th>
<td class="pes-text-left">
<div>10 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Length</th>
<td class="pes-text-left">
<div>22.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 3</th>
<td class="pes-text-left">
<div>S03</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 3</th>
<td class="pes-text-left">
<div>44</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Weight</th>
<td class="pes-text-left">
<div>18.826 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Height</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 width</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Length</th>
<td class="pes-text-left">
<div>40 cm</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Offer Sustainability</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Sustainable offer status</th>
<td class="pes-text-left">
<div>Green Premium product</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfReach&amp;pid=13672230&amp;lang=en-us" target="" rel="noopener">REACh Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh free of SVHC</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">EU RoHS Directive</th>
<td class="pes-text-left">
<div>Compliant<br />
<a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672230&amp;lang=en-us" target="" rel="noopener">EU RoHS Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Toxic heavy metal free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mercury free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">RoHS exemption information</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672230&amp;lang=en-us" target="" rel="noopener">Yes</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">China RoHS Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfRoHsChina&amp;pid=13672230&amp;lang=en-us" target="" rel="noopener">China RoHS declaration</a><br />
Pro-active China RoHS declaration (out of China RoHS legal scope)</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Environmental Disclosure</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://download.schneider-electric.com/files?p_Doc_Ref=ENVPEP1409009EN" target="" rel="noopener">Product Environmental Profile</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">WEEE</th>
<td class="pes-text-left">
<div>The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Contractual warranty</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Warranty</th>
<td class="pes-text-left">
<div>18 months</div>
</td>
</tr>
</tbody>
</table>
<p></div><div id="tab-5fff0001672bd" class="lvca-tab-pane">Tel: 01206 862 062</p>
<p>Email: <a href="mailto:sales@electrogear.co.uk">sales@electrogear.co.uk</a></p>
<p>More Information <strong>CLICK HERE</strong></div></div></div>            <style type="text/css">
                                #lvca-tabs-6a52a0e6e8a43.lvca-style8 .lvca-tab-nav .lvca-tab.lvca-active a {
                    border-left-color: #004b96;
                }
                            </style>
            </div></div></div></div></div><p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-63a/">Schneider Acti9 3P D Curve 63A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Schneider Acti9 3P D Curve 50A</title>
		<link>https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-50a/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=schneider-acti9-3p-d-curve-50a</link>
		
		<dc:creator><![CDATA[electrogear-user]]></dc:creator>
		<pubDate>Tue, 24 Aug 2021 15:03:37 +0000</pubDate>
				<guid isPermaLink="false">https://electrogear.co.uk/?post_type=product&#038;p=24558</guid>

					<description><![CDATA[<p>A9F85350</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-50a/">Schneider Acti9 3P D Curve 50A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></description>
										<content:encoded><![CDATA[<div     class="vc_row wpb_row section vc_row-fluid " style=' padding-bottom:50px; text-align:left;'><div class=" full_section_inner clearfix"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div id="lvca-tabs-6a52a0e6eada9" class="lvca-tabs lvca-vertical lvca-style8" data-mobile-width="600"><a href="#" class="lvca-tab-mobile-menu"><i class="lvca-icon-menu"></i>&nbsp;</a><div class="lvca-tab-nav"><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">OVERVIEW</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">DETAILS</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">MORE INFORMATION</span></a></div></div><div class="lvca-tab-panes"><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<h3 data-testid="descriptive-content-main-header"><b>Schneider Electric | Acti9 iC60H | Mini Circuit Breakers</b></h3>
<p>&nbsp;</p>
<p>The Acti9 series of MCBs by Schneider Electric provides excellent circuit protection particularly in combating short circuits and overload currents. These MCBs are rigorously tested by Schneider and are compliant with standards such as IEC/EN 60898 &amp; 60947-2. These types of MCBs are typically used in industrial or commercial buildings and can work extremely well in polluted environments.</p>
<p>&nbsp;</p>
<h3 data-testid="descriptive-content-main-header"><b>Features and benefits:</b></h3>
<p>&nbsp;</p>
<p>• Easy to install these consumer units, single clip on to Din Rail, compact in nature making wiring easier and simplifying your circuit system. Ergonomically designed with robust connections. IP20B terminal shutters.</p>
<p>• Schneider &#8216;VisiSafe&#8217; for safer operation and maintenance work on electrical circuits. Absolute safety of circuit protection guaranteed.</p>
<p>• Schneider &#8216;VisiTrip&#8217; for easier fault detection in the MCB outgoers. This can help reduce intervention time greatly, protecting the device before any further electrical problems occur.</div><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<table class="pes-table">
<tbody>
<tr>
<th class="pes-text-left char-table__title">Device application</th>
<td class="pes-text-left">
<div>Distribution</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">range</th>
<td class="pes-text-left">
<div>Acti 9</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">product name</th>
<td class="pes-text-left">
<div>Acti 9 iC60</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Product or component type</th>
<td class="pes-text-left">
<div>Miniature circuit-breaker</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">device short name</th>
<td class="pes-text-left">
<div>IC60H</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">poles description</th>
<td class="pes-text-left">
<div>3P</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">number of protected poles</th>
<td class="pes-text-left">
<div>3</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[In] rated current</th>
<td class="pes-text-left">
<div>50 A</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">network type</th>
<td class="pes-text-left">
<div>DC<br />
AC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">trip unit technology</th>
<td class="pes-text-left">
<div>Thermal-magnetic</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">curve code</th>
<td class="pes-text-left">
<div>D</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">breaking capacity</th>
<td class="pes-text-left">
<div>10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1<br />
42 kA Icu at 12&#8230;60 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at 380&#8230;415 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
30 kA Icu at 220&#8230;240 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
42 kA Icu at 100&#8230;133 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at &lt;= 180 V DC conforming to EN/IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">utilisation category</th>
<td class="pes-text-left">
<div>Category A conforming to EN 60947-2<br />
Category A conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">suitability for isolation</th>
<td class="pes-text-left">
<div>Yes conforming to EN 60898-1<br />
Yes conforming to EN 60947-2<br />
Yes conforming to IEC 60898-1<br />
Yes conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">standards</th>
<td class="pes-text-left">
<div>EN 60947-2<br />
IEC 60947-2<br />
IEC 60898-1<br />
EN 60898-1</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Complementary</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Network frequency</th>
<td class="pes-text-left">
<div>50/60 Hz</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">magnetic tripping limit</th>
<td class="pes-text-left">
<div>12 x In +/- 20 %</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ics] rated service breaking capacity</th>
<td class="pes-text-left">
<div>15 kA 50 % conforming to EN 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to EN 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to EN 60947-2 &#8211; 440 V AC 50/60 Hz<br />
15 kA 50 % conforming to IEC 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to IEC 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to IEC 60947-2 &#8211; 440 V AC 50/60 Hz<br />
7500 A 75 % conforming to EN 60898-1 &#8211; 400 V AC 50/60 Hz<br />
7500 A 75 % conforming to IEC 60898-1 &#8211; 400 V AC 50/60 Hz<br />
21 kA 50 % conforming to IEC 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
21 kA 50 % conforming to EN 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
15 kA 100 % conforming to IEC 60947-2 &#8211; 125&#8230;180 V DC<br />
15 kA 100 % conforming to EN 60947-2 &#8211; 125&#8230;180 V DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">limitation class</th>
<td class="pes-text-left">
<div>3 conforming to EN 60898-1<br />
3 conforming to IEC 60898-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ui] rated insulation voltage</th>
<td class="pes-text-left">
<div>500 V AC 50/60 Hz conforming to EN 60947-2<br />
500 V AC 50/60 Hz conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Uimp] rated impulse withstand voltage</th>
<td class="pes-text-left">
<div>6 kV conforming to EN 60947-2<br />
6 kV conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">contact position indicator</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Control type</th>
<td class="pes-text-left">
<div>Toggle</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">local signalling</th>
<td class="pes-text-left">
<div>Trip indicator</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting mode</th>
<td class="pes-text-left">
<div>Fixed</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting support</th>
<td class="pes-text-left">
<div>DIN rail</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">comb busbar and distribution block compatibility</th>
<td class="pes-text-left">
<div>Top or bottom: YES</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">9 mm pitches</th>
<td class="pes-text-left">
<div>6</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Height</th>
<td class="pes-text-left">
<div>85 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Width</th>
<td class="pes-text-left">
<div>54 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Depth</th>
<td class="pes-text-left">
<div>78.5 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Net weight</th>
<td class="pes-text-left">
<div>0.375 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">colour</th>
<td class="pes-text-left">
<div>White</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">mechanical durability</th>
<td class="pes-text-left">
<div>20000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">electrical durability</th>
<td class="pes-text-left">
<div>10000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">connections &#8211; terminals</th>
<td class="pes-text-left">
<div>Single terminal (top or bottom) 1…35 mm² rigid<br />
Single terminal (top or bottom) 1…25 mm² flexible</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">wire stripping length</th>
<td class="pes-text-left">
<div>14 mm for top or bottom connection</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tightening torque</th>
<td class="pes-text-left">
<div>3.5 N.m top or bottom</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">earth-leakage protection</th>
<td class="pes-text-left">
<div>Separate block</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Environment</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">IP degree of protection</th>
<td class="pes-text-left">
<div>IP20 conforming to IEC 60529<br />
IP20 conforming to EN 60529</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">pollution degree</th>
<td class="pes-text-left">
<div>3 conforming to EN 60947-2<br />
3 conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">overvoltage category</th>
<td class="pes-text-left">
<div>IV</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tropicalisation</th>
<td class="pes-text-left">
<div>2 conforming to IEC 60068-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">relative humidity</th>
<td class="pes-text-left">
<div>95 % at 55 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">operating altitude</th>
<td class="pes-text-left">
<div>0&#8230;2000 m</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for operation</th>
<td class="pes-text-left">
<div>-35…70 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for storage</th>
<td class="pes-text-left">
<div>-40…85 °C</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Packing Units</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 1</th>
<td class="pes-text-left">
<div>PCE</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 1</th>
<td class="pes-text-left">
<div>1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Weight</th>
<td class="pes-text-left">
<div>402 g</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Height</th>
<td class="pes-text-left">
<div>5.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 width</th>
<td class="pes-text-left">
<div>7.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Length</th>
<td class="pes-text-left">
<div>9.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 2</th>
<td class="pes-text-left">
<div>BB1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 2</th>
<td class="pes-text-left">
<div>4</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Weight</th>
<td class="pes-text-left">
<div>1.676 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Height</th>
<td class="pes-text-left">
<div>10 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 width</th>
<td class="pes-text-left">
<div>8 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Length</th>
<td class="pes-text-left">
<div>23 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 3</th>
<td class="pes-text-left">
<div>S03</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 3</th>
<td class="pes-text-left">
<div>44</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Weight</th>
<td class="pes-text-left">
<div>18.983 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Height</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 width</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Length</th>
<td class="pes-text-left">
<div>40 cm</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Offer Sustainability</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Sustainable offer status</th>
<td class="pes-text-left">
<div>Green Premium product</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfReach&amp;pid=13672228&amp;lang=en-us" target="" rel="noopener">REACh Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh free of SVHC</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">EU RoHS Directive</th>
<td class="pes-text-left">
<div>Compliant<br />
<a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672228&amp;lang=en-us" target="" rel="noopener">EU RoHS Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Toxic heavy metal free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mercury free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">RoHS exemption information</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672228&amp;lang=en-us" target="" rel="noopener">Yes</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">China RoHS Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfRoHsChina&amp;pid=13672228&amp;lang=en-us" target="" rel="noopener">China RoHS declaration</a><br />
Pro-active China RoHS declaration (out of China RoHS legal scope)</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Environmental Disclosure</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://download.schneider-electric.com/files?p_Doc_Ref=ENVPEP1409009EN" target="" rel="noopener">Product Environmental Profile</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">WEEE</th>
<td class="pes-text-left">
<div>The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Contractual warranty</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Warranty</th>
<td class="pes-text-left">
<div>18 months</div>
</td>
</tr>
</tbody>
</table>
<p></div><div id="tab-5fff0001672bd" class="lvca-tab-pane">Tel: 01206 862 062</p>
<p>Email: <a href="mailto:sales@electrogear.co.uk">sales@electrogear.co.uk</a></p>
<p>More Information <strong>CLICK HERE</strong></div></div></div>            <style type="text/css">
                                #lvca-tabs-6a52a0e6eada9.lvca-style8 .lvca-tab-nav .lvca-tab.lvca-active a {
                    border-left-color: #004b96;
                }
                            </style>
            </div></div></div></div></div><p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-50a/">Schneider Acti9 3P D Curve 50A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Schneider Acti9 3P D Curve 40A</title>
		<link>https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-40a/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=schneider-acti9-3p-d-curve-40a</link>
		
		<dc:creator><![CDATA[electrogear-user]]></dc:creator>
		<pubDate>Tue, 24 Aug 2021 15:01:00 +0000</pubDate>
				<guid isPermaLink="false">https://electrogear.co.uk/?post_type=product&#038;p=24556</guid>

					<description><![CDATA[<p>A9F85340</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-40a/">Schneider Acti9 3P D Curve 40A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></description>
										<content:encoded><![CDATA[<div     class="vc_row wpb_row section vc_row-fluid " style=' padding-bottom:50px; text-align:left;'><div class=" full_section_inner clearfix"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div id="lvca-tabs-6a52a0e6ed010" class="lvca-tabs lvca-vertical lvca-style8" data-mobile-width="600"><a href="#" class="lvca-tab-mobile-menu"><i class="lvca-icon-menu"></i>&nbsp;</a><div class="lvca-tab-nav"><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">OVERVIEW</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">DETAILS</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">MORE INFORMATION</span></a></div></div><div class="lvca-tab-panes"><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<h3 data-testid="descriptive-content-main-header"><b>Schneider Electric | Acti9 iC60H | Mini Circuit Breakers</b></h3>
<p>&nbsp;</p>
<p>The Acti9 series of MCBs by Schneider Electric provides excellent circuit protection particularly in combating short circuits and overload currents. These MCBs are rigorously tested by Schneider and are compliant with standards such as IEC/EN 60898 &amp; 60947-2. These types of MCBs are typically used in industrial or commercial buildings and can work extremely well in polluted environments.</p>
<p>&nbsp;</p>
<h3 data-testid="descriptive-content-main-header"><b>Features and benefits:</b></h3>
<p>&nbsp;</p>
<p>• Easy to install these consumer units, single clip on to Din Rail, compact in nature making wiring easier and simplifying your circuit system. Ergonomically designed with robust connections. IP20B terminal shutters.</p>
<p>• Schneider &#8216;VisiSafe&#8217; for safer operation and maintenance work on electrical circuits. Absolute safety of circuit protection guaranteed.</p>
<p>• Schneider &#8216;VisiTrip&#8217; for easier fault detection in the MCB outgoers. This can help reduce intervention time greatly, protecting the device before any further electrical problems occur.</div><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<table class="pes-table">
<tbody>
<tr>
<th class="pes-text-left char-table__title">Device application</th>
<td class="pes-text-left">
<div>Distribution</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">range</th>
<td class="pes-text-left">
<div>Acti 9</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">product name</th>
<td class="pes-text-left">
<div>Acti 9 iC60</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Product or component type</th>
<td class="pes-text-left">
<div>Miniature circuit-breaker</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">device short name</th>
<td class="pes-text-left">
<div>IC60H</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">poles description</th>
<td class="pes-text-left">
<div>3P</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">number of protected poles</th>
<td class="pes-text-left">
<div>3</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[In] rated current</th>
<td class="pes-text-left">
<div>40 A</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">network type</th>
<td class="pes-text-left">
<div>AC<br />
DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">trip unit technology</th>
<td class="pes-text-left">
<div>Thermal-magnetic</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">curve code</th>
<td class="pes-text-left">
<div>D</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">breaking capacity</th>
<td class="pes-text-left">
<div>10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1<br />
42 kA Icu at 12&#8230;60 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at 380&#8230;415 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
30 kA Icu at 220&#8230;240 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
42 kA Icu at 100&#8230;133 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at &lt;= 180 V DC conforming to EN/IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">utilisation category</th>
<td class="pes-text-left">
<div>Category A conforming to EN 60947-2<br />
Category A conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">suitability for isolation</th>
<td class="pes-text-left">
<div>Yes conforming to EN 60898-1<br />
Yes conforming to EN 60947-2<br />
Yes conforming to IEC 60898-1<br />
Yes conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">standards</th>
<td class="pes-text-left">
<div>EN 60947-2<br />
EN 60898-1<br />
IEC 60947-2<br />
IEC 60898-1</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Complementary</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Network frequency</th>
<td class="pes-text-left">
<div>50/60 Hz</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">magnetic tripping limit</th>
<td class="pes-text-left">
<div>12 x In +/- 20 %</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ics] rated service breaking capacity</th>
<td class="pes-text-left">
<div>15 kA 50 % conforming to EN 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to EN 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to EN 60947-2 &#8211; 440 V AC 50/60 Hz<br />
15 kA 50 % conforming to IEC 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to IEC 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to IEC 60947-2 &#8211; 440 V AC 50/60 Hz<br />
7500 A 75 % conforming to EN 60898-1 &#8211; 400 V AC 50/60 Hz<br />
7500 A 75 % conforming to IEC 60898-1 &#8211; 400 V AC 50/60 Hz<br />
21 kA 50 % conforming to IEC 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
21 kA 50 % conforming to EN 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
15 kA 100 % conforming to IEC 60947-2 &#8211; 125&#8230;180 V DC<br />
15 kA 100 % conforming to EN 60947-2 &#8211; 125&#8230;180 V DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">limitation class</th>
<td class="pes-text-left">
<div>3 conforming to EN 60898-1<br />
3 conforming to IEC 60898-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ui] rated insulation voltage</th>
<td class="pes-text-left">
<div>500 V AC 50/60 Hz conforming to EN 60947-2<br />
500 V AC 50/60 Hz conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Uimp] rated impulse withstand voltage</th>
<td class="pes-text-left">
<div>6 kV conforming to EN 60947-2<br />
6 kV conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">contact position indicator</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Control type</th>
<td class="pes-text-left">
<div>Toggle</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">local signalling</th>
<td class="pes-text-left">
<div>Trip indicator</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting mode</th>
<td class="pes-text-left">
<div>Fixed</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting support</th>
<td class="pes-text-left">
<div>DIN rail</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">comb busbar and distribution block compatibility</th>
<td class="pes-text-left">
<div>Top or bottom: YES</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">9 mm pitches</th>
<td class="pes-text-left">
<div>6</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Height</th>
<td class="pes-text-left">
<div>85 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Width</th>
<td class="pes-text-left">
<div>54 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Depth</th>
<td class="pes-text-left">
<div>78.5 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Net weight</th>
<td class="pes-text-left">
<div>0.375 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">colour</th>
<td class="pes-text-left">
<div>White</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">mechanical durability</th>
<td class="pes-text-left">
<div>20000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">electrical durability</th>
<td class="pes-text-left">
<div>10000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">connections &#8211; terminals</th>
<td class="pes-text-left">
<div>Single terminal (top or bottom) 1…35 mm² rigid<br />
Single terminal (top or bottom) 1…25 mm² flexible</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">wire stripping length</th>
<td class="pes-text-left">
<div>14 mm for top or bottom connection</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tightening torque</th>
<td class="pes-text-left">
<div>3.5 N.m top or bottom</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">earth-leakage protection</th>
<td class="pes-text-left">
<div>Separate block</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Environment</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">IP degree of protection</th>
<td class="pes-text-left">
<div>IP20 conforming to IEC 60529<br />
IP20 conforming to EN 60529</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">pollution degree</th>
<td class="pes-text-left">
<div>3 conforming to EN 60947-2<br />
3 conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">overvoltage category</th>
<td class="pes-text-left">
<div>IV</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tropicalisation</th>
<td class="pes-text-left">
<div>2 conforming to IEC 60068-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">relative humidity</th>
<td class="pes-text-left">
<div>95 % at 55 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">operating altitude</th>
<td class="pes-text-left">
<div>0&#8230;2000 m</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for operation</th>
<td class="pes-text-left">
<div>-35…70 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for storage</th>
<td class="pes-text-left">
<div>-40…85 °C</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Packing Units</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 1</th>
<td class="pes-text-left">
<div>PCE</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 1</th>
<td class="pes-text-left">
<div>1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Weight</th>
<td class="pes-text-left">
<div>374 g</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Height</th>
<td class="pes-text-left">
<div>5.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 width</th>
<td class="pes-text-left">
<div>7.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Length</th>
<td class="pes-text-left">
<div>9.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 2</th>
<td class="pes-text-left">
<div>BB1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 2</th>
<td class="pes-text-left">
<div>4</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Weight</th>
<td class="pes-text-left">
<div>1.561 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Height</th>
<td class="pes-text-left">
<div>8 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 width</th>
<td class="pes-text-left">
<div>10 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Length</th>
<td class="pes-text-left">
<div>22.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 3</th>
<td class="pes-text-left">
<div>S03</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 3</th>
<td class="pes-text-left">
<div>44</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Weight</th>
<td class="pes-text-left">
<div>17.607 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Height</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 width</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Length</th>
<td class="pes-text-left">
<div>40 cm</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Offer Sustainability</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Sustainable offer status</th>
<td class="pes-text-left">
<div>Green Premium product</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfReach&amp;pid=13672226&amp;lang=en-us" target="" rel="noopener">REACh Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh free of SVHC</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">EU RoHS Directive</th>
<td class="pes-text-left">
<div>Compliant<br />
<a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672226&amp;lang=en-us" target="" rel="noopener">EU RoHS Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Toxic heavy metal free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mercury free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">RoHS exemption information</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672226&amp;lang=en-us" target="" rel="noopener">Yes</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">China RoHS Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfRoHsChina&amp;pid=13672226&amp;lang=en-us" target="" rel="noopener">China RoHS declaration</a><br />
Pro-active China RoHS declaration (out of China RoHS legal scope)</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Environmental Disclosure</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://download.schneider-electric.com/files?p_Doc_Ref=ENVPEP1409009EN" target="" rel="noopener">Product Environmental Profile</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">WEEE</th>
<td class="pes-text-left">
<div>The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Contractual warranty</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Warranty</th>
<td class="pes-text-left">
<div>18 months</div>
</td>
</tr>
</tbody>
</table>
<p></div><div id="tab-5fff0001672bd" class="lvca-tab-pane">Tel: 01206 862 062</p>
<p>Email: <a href="mailto:sales@electrogear.co.uk">sales@electrogear.co.uk</a></p>
<p>More Information <strong>CLICK HERE</strong></div></div></div>            <style type="text/css">
                                #lvca-tabs-6a52a0e6ed010.lvca-style8 .lvca-tab-nav .lvca-tab.lvca-active a {
                    border-left-color: #004b96;
                }
                            </style>
            </div></div></div></div></div><p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-40a/">Schneider Acti9 3P D Curve 40A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Schneider Acti9 3P D Curve 32A</title>
		<link>https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-32a/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=schneider-acti9-3p-d-curve-32a</link>
		
		<dc:creator><![CDATA[electrogear-user]]></dc:creator>
		<pubDate>Tue, 24 Aug 2021 14:50:12 +0000</pubDate>
				<guid isPermaLink="false">https://electrogear.co.uk/?post_type=product&#038;p=24554</guid>

					<description><![CDATA[<p>A9F85332</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-32a/">Schneider Acti9 3P D Curve 32A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></description>
										<content:encoded><![CDATA[<div     class="vc_row wpb_row section vc_row-fluid " style=' padding-bottom:50px; text-align:left;'><div class=" full_section_inner clearfix"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div id="lvca-tabs-6a52a0e6ef345" class="lvca-tabs lvca-vertical lvca-style8" data-mobile-width="600"><a href="#" class="lvca-tab-mobile-menu"><i class="lvca-icon-menu"></i>&nbsp;</a><div class="lvca-tab-nav"><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">OVERVIEW</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">DETAILS</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">MORE INFORMATION</span></a></div></div><div class="lvca-tab-panes"><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<h3 data-testid="descriptive-content-main-header"><b>Schneider Electric | Acti9 iC60H | Mini Circuit Breakers</b></h3>
<p>&nbsp;</p>
<p>The Acti9 series of MCBs by Schneider Electric provides excellent circuit protection particularly in combating short circuits and overload currents. These MCBs are rigorously tested by Schneider and are compliant with standards such as IEC/EN 60898 &amp; 60947-2. These types of MCBs are typically used in industrial or commercial buildings and can work extremely well in polluted environments.</p>
<p>&nbsp;</p>
<h3 data-testid="descriptive-content-main-header"><b>Features and benefits:</b></h3>
<p>&nbsp;</p>
<p>• Easy to install these consumer units, single clip on to Din Rail, compact in nature making wiring easier and simplifying your circuit system. Ergonomically designed with robust connections. IP20B terminal shutters.</p>
<p>• Schneider &#8216;VisiSafe&#8217; for safer operation and maintenance work on electrical circuits. Absolute safety of circuit protection guaranteed.</p>
<p>• Schneider &#8216;VisiTrip&#8217; for easier fault detection in the MCB outgoers. This can help reduce intervention time greatly, protecting the device before any further electrical problems occur.</div><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<table class="pes-table">
<tbody>
<tr>
<th class="pes-text-left char-table__title">Device application</th>
<td class="pes-text-left">
<div>Distribution</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">range</th>
<td class="pes-text-left">
<div>Acti 9</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">product name</th>
<td class="pes-text-left">
<div>Acti 9 iC60</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Product or component type</th>
<td class="pes-text-left">
<div>Miniature circuit-breaker</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">device short name</th>
<td class="pes-text-left">
<div>IC60H</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">poles description</th>
<td class="pes-text-left">
<div>3P</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">number of protected poles</th>
<td class="pes-text-left">
<div>3</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[In] rated current</th>
<td class="pes-text-left">
<div>32 A</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">network type</th>
<td class="pes-text-left">
<div>AC<br />
DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">trip unit technology</th>
<td class="pes-text-left">
<div>Thermal-magnetic</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">curve code</th>
<td class="pes-text-left">
<div>D</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">breaking capacity</th>
<td class="pes-text-left">
<div>10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1<br />
42 kA Icu at 12&#8230;60 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at 380&#8230;415 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
30 kA Icu at 220&#8230;240 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
42 kA Icu at 100&#8230;133 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at &lt;= 180 V DC conforming to EN/IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">utilisation category</th>
<td class="pes-text-left">
<div>Category A conforming to EN 60947-2<br />
Category A conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">suitability for isolation</th>
<td class="pes-text-left">
<div>Yes conforming to EN 60898-1<br />
Yes conforming to EN 60947-2<br />
Yes conforming to IEC 60898-1<br />
Yes conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">standards</th>
<td class="pes-text-left">
<div>EN 60898-1<br />
IEC 60898-1<br />
IEC 60947-2<br />
EN 60947-2</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Complementary</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Network frequency</th>
<td class="pes-text-left">
<div>50/60 Hz</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">magnetic tripping limit</th>
<td class="pes-text-left">
<div>12 x In +/- 20 %</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ics] rated service breaking capacity</th>
<td class="pes-text-left">
<div>15 kA 50 % conforming to EN 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to EN 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to EN 60947-2 &#8211; 440 V AC 50/60 Hz<br />
15 kA 50 % conforming to IEC 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to IEC 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to IEC 60947-2 &#8211; 440 V AC 50/60 Hz<br />
7500 A 75 % conforming to EN 60898-1 &#8211; 400 V AC 50/60 Hz<br />
7500 A 75 % conforming to IEC 60898-1 &#8211; 400 V AC 50/60 Hz<br />
21 kA 50 % conforming to IEC 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
21 kA 50 % conforming to EN 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
15 kA 100 % conforming to IEC 60947-2 &#8211; 125&#8230;180 V DC<br />
15 kA 100 % conforming to EN 60947-2 &#8211; 125&#8230;180 V DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">limitation class</th>
<td class="pes-text-left">
<div>3 conforming to EN 60898-1<br />
3 conforming to IEC 60898-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ui] rated insulation voltage</th>
<td class="pes-text-left">
<div>500 V AC 50/60 Hz conforming to EN 60947-2<br />
500 V AC 50/60 Hz conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Uimp] rated impulse withstand voltage</th>
<td class="pes-text-left">
<div>6 kV conforming to EN 60947-2<br />
6 kV conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">contact position indicator</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Control type</th>
<td class="pes-text-left">
<div>Toggle</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">local signalling</th>
<td class="pes-text-left">
<div>Trip indicator</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting mode</th>
<td class="pes-text-left">
<div>Fixed</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting support</th>
<td class="pes-text-left">
<div>DIN rail</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">comb busbar and distribution block compatibility</th>
<td class="pes-text-left">
<div>Top or bottom: YES</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">9 mm pitches</th>
<td class="pes-text-left">
<div>6</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Height</th>
<td class="pes-text-left">
<div>85 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Width</th>
<td class="pes-text-left">
<div>54 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Depth</th>
<td class="pes-text-left">
<div>78.5 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Net weight</th>
<td class="pes-text-left">
<div>0.375 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">colour</th>
<td class="pes-text-left">
<div>White</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">mechanical durability</th>
<td class="pes-text-left">
<div>20000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">electrical durability</th>
<td class="pes-text-left">
<div>10000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">connections &#8211; terminals</th>
<td class="pes-text-left">
<div>Single terminal (top or bottom) 1…35 mm² rigid<br />
Single terminal (top or bottom) 1…25 mm² flexible</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">wire stripping length</th>
<td class="pes-text-left">
<div>14 mm for top or bottom connection</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tightening torque</th>
<td class="pes-text-left">
<div>3.5 N.m top or bottom</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">earth-leakage protection</th>
<td class="pes-text-left">
<div>Separate block</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Environment</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">IP degree of protection</th>
<td class="pes-text-left">
<div>IP20 conforming to IEC 60529<br />
IP20 conforming to EN 60529</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">pollution degree</th>
<td class="pes-text-left">
<div>3 conforming to EN 60947-2<br />
3 conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">overvoltage category</th>
<td class="pes-text-left">
<div>IV</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tropicalisation</th>
<td class="pes-text-left">
<div>2 conforming to IEC 60068-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">relative humidity</th>
<td class="pes-text-left">
<div>95 % at 55 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">operating altitude</th>
<td class="pes-text-left">
<div>0&#8230;2000 m</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for operation</th>
<td class="pes-text-left">
<div>-35…70 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for storage</th>
<td class="pes-text-left">
<div>-40…85 °C</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Packing Units</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 1</th>
<td class="pes-text-left">
<div>PCE</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 1</th>
<td class="pes-text-left">
<div>1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Weight</th>
<td class="pes-text-left">
<div>375 g</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Height</th>
<td class="pes-text-left">
<div>5.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 width</th>
<td class="pes-text-left">
<div>7.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Length</th>
<td class="pes-text-left">
<div>9.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 2</th>
<td class="pes-text-left">
<div>BB1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 2</th>
<td class="pes-text-left">
<div>4</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Weight</th>
<td class="pes-text-left">
<div>1.568 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Height</th>
<td class="pes-text-left">
<div>10 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 width</th>
<td class="pes-text-left">
<div>8 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Length</th>
<td class="pes-text-left">
<div>23 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 3</th>
<td class="pes-text-left">
<div>S03</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 3</th>
<td class="pes-text-left">
<div>44</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Weight</th>
<td class="pes-text-left">
<div>17.574 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Height</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 width</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Length</th>
<td class="pes-text-left">
<div>40 cm</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Offer Sustainability</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Sustainable offer status</th>
<td class="pes-text-left">
<div>Green Premium product</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfReach&amp;pid=13672224&amp;lang=en-us" target="" rel="noopener">REACh Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh free of SVHC</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">EU RoHS Directive</th>
<td class="pes-text-left">
<div>Compliant<br />
<a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672224&amp;lang=en-us" target="" rel="noopener">EU RoHS Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Toxic heavy metal free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mercury free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">RoHS exemption information</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672224&amp;lang=en-us" target="" rel="noopener">Yes</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">China RoHS Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfRoHsChina&amp;pid=13672224&amp;lang=en-us" target="" rel="noopener">China RoHS declaration</a><br />
Pro-active China RoHS declaration (out of China RoHS legal scope)</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Environmental Disclosure</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://download.schneider-electric.com/files?p_Doc_Ref=ENVPEP1409009EN" target="" rel="noopener">Product Environmental Profile</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">WEEE</th>
<td class="pes-text-left">
<div>The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Contractual warranty</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Warranty</th>
<td class="pes-text-left">
<div>18 months</div>
</td>
</tr>
</tbody>
</table>
<p></div><div id="tab-5fff0001672bd" class="lvca-tab-pane">Tel: 01206 862 062</p>
<p>Email: <a href="mailto:sales@electrogear.co.uk">sales@electrogear.co.uk</a></p>
<p>More Information <strong>CLICK HERE</strong></div></div></div>            <style type="text/css">
                                #lvca-tabs-6a52a0e6ef345.lvca-style8 .lvca-tab-nav .lvca-tab.lvca-active a {
                    border-left-color: #004b96;
                }
                            </style>
            </div></div></div></div></div><p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-32a/">Schneider Acti9 3P D Curve 32A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Schneider Acti9 3P D Curve 25A</title>
		<link>https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-25a/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=schneider-acti9-3p-d-curve-25a</link>
		
		<dc:creator><![CDATA[electrogear-user]]></dc:creator>
		<pubDate>Tue, 24 Aug 2021 14:47:46 +0000</pubDate>
				<guid isPermaLink="false">https://electrogear.co.uk/?post_type=product&#038;p=24552</guid>

					<description><![CDATA[<p>A9F85325</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-25a/">Schneider Acti9 3P D Curve 25A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></description>
										<content:encoded><![CDATA[<div     class="vc_row wpb_row section vc_row-fluid " style=' padding-bottom:50px; text-align:left;'><div class=" full_section_inner clearfix"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div id="lvca-tabs-6a52a0e6f17d9" class="lvca-tabs lvca-vertical lvca-style8" data-mobile-width="600"><a href="#" class="lvca-tab-mobile-menu"><i class="lvca-icon-menu"></i>&nbsp;</a><div class="lvca-tab-nav"><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">OVERVIEW</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">DETAILS</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">MORE INFORMATION</span></a></div></div><div class="lvca-tab-panes"><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<h3 data-testid="descriptive-content-main-header"><b>Schneider Electric | Acti9 iC60H | Mini Circuit Breakers</b></h3>
<p>&nbsp;</p>
<p>The Acti9 series of MCBs by Schneider Electric provides excellent circuit protection particularly in combating short circuits and overload currents. These MCBs are rigorously tested by Schneider and are compliant with standards such as IEC/EN 60898 &amp; 60947-2. These types of MCBs are typically used in industrial or commercial buildings and can work extremely well in polluted environments.</p>
<p>&nbsp;</p>
<h3 data-testid="descriptive-content-main-header"><b>Features and benefits:</b></h3>
<p>&nbsp;</p>
<p>• Easy to install these consumer units, single clip on to Din Rail, compact in nature making wiring easier and simplifying your circuit system. Ergonomically designed with robust connections. IP20B terminal shutters.</p>
<p>• Schneider &#8216;VisiSafe&#8217; for safer operation and maintenance work on electrical circuits. Absolute safety of circuit protection guaranteed.</p>
<p>• Schneider &#8216;VisiTrip&#8217; for easier fault detection in the MCB outgoers. This can help reduce intervention time greatly, protecting the device before any further electrical problems occur.</div><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<table class="pes-table">
<tbody>
<tr>
<th class="pes-text-left char-table__title">Device application</th>
<td class="pes-text-left">
<div>Distribution</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">range</th>
<td class="pes-text-left">
<div>Acti 9</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">product name</th>
<td class="pes-text-left">
<div>Acti 9 iC60</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Product or component type</th>
<td class="pes-text-left">
<div>Miniature circuit-breaker</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">device short name</th>
<td class="pes-text-left">
<div>IC60H</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">poles description</th>
<td class="pes-text-left">
<div>3P</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">number of protected poles</th>
<td class="pes-text-left">
<div>3</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[In] rated current</th>
<td class="pes-text-left">
<div>25 A</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">network type</th>
<td class="pes-text-left">
<div>DC<br />
AC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">trip unit technology</th>
<td class="pes-text-left">
<div>Thermal-magnetic</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">curve code</th>
<td class="pes-text-left">
<div>D</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">breaking capacity</th>
<td class="pes-text-left">
<div>10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1<br />
42 kA Icu at 12&#8230;60 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at 380&#8230;415 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
30 kA Icu at 220&#8230;240 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
42 kA Icu at 100&#8230;133 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at &lt;= 180 V DC conforming to EN/IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">utilisation category</th>
<td class="pes-text-left">
<div>Category A conforming to EN 60947-2<br />
Category A conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">suitability for isolation</th>
<td class="pes-text-left">
<div>Yes conforming to EN 60898-1<br />
Yes conforming to EN 60947-2<br />
Yes conforming to IEC 60898-1<br />
Yes conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">standards</th>
<td class="pes-text-left">
<div>EN 60898-1<br />
EN 60947-2<br />
IEC 60947-2<br />
IEC 60898-1</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Complementary</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Network frequency</th>
<td class="pes-text-left">
<div>50/60 Hz</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">magnetic tripping limit</th>
<td class="pes-text-left">
<div>12 x In +/- 20 %</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ics] rated service breaking capacity</th>
<td class="pes-text-left">
<div>15 kA 50 % conforming to EN 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to EN 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to EN 60947-2 &#8211; 440 V AC 50/60 Hz<br />
15 kA 50 % conforming to IEC 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to IEC 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to IEC 60947-2 &#8211; 440 V AC 50/60 Hz<br />
7500 A 75 % conforming to EN 60898-1 &#8211; 400 V AC 50/60 Hz<br />
7500 A 75 % conforming to IEC 60898-1 &#8211; 400 V AC 50/60 Hz<br />
21 kA 50 % conforming to IEC 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
21 kA 50 % conforming to EN 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
15 kA 100 % conforming to IEC 60947-2 &#8211; 125&#8230;180 V DC<br />
15 kA 100 % conforming to EN 60947-2 &#8211; 125&#8230;180 V DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">limitation class</th>
<td class="pes-text-left">
<div>3 conforming to EN 60898-1<br />
3 conforming to IEC 60898-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ui] rated insulation voltage</th>
<td class="pes-text-left">
<div>500 V AC 50/60 Hz conforming to EN 60947-2<br />
500 V AC 50/60 Hz conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Uimp] rated impulse withstand voltage</th>
<td class="pes-text-left">
<div>6 kV conforming to EN 60947-2<br />
6 kV conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">contact position indicator</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Control type</th>
<td class="pes-text-left">
<div>Toggle</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">local signalling</th>
<td class="pes-text-left">
<div>Trip indicator</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting mode</th>
<td class="pes-text-left">
<div>Fixed</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting support</th>
<td class="pes-text-left">
<div>DIN rail</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">comb busbar and distribution block compatibility</th>
<td class="pes-text-left">
<div>Top or bottom: YES</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">9 mm pitches</th>
<td class="pes-text-left">
<div>6</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Height</th>
<td class="pes-text-left">
<div>85 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Width</th>
<td class="pes-text-left">
<div>54 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Depth</th>
<td class="pes-text-left">
<div>78.5 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Net weight</th>
<td class="pes-text-left">
<div>0.375 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">colour</th>
<td class="pes-text-left">
<div>White</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">mechanical durability</th>
<td class="pes-text-left">
<div>20000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">electrical durability</th>
<td class="pes-text-left">
<div>10000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">connections &#8211; terminals</th>
<td class="pes-text-left">
<div>Single terminal (top or bottom) 1…25 mm² rigid<br />
Single terminal (top or bottom) 1…16 mm² flexible</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">wire stripping length</th>
<td class="pes-text-left">
<div>14 mm for top or bottom connection</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tightening torque</th>
<td class="pes-text-left">
<div>2 N.m top or bottom</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">earth-leakage protection</th>
<td class="pes-text-left">
<div>Separate block</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Environment</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">IP degree of protection</th>
<td class="pes-text-left">
<div>IP20 conforming to IEC 60529<br />
IP20 conforming to EN 60529</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">pollution degree</th>
<td class="pes-text-left">
<div>3 conforming to EN 60947-2<br />
3 conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">overvoltage category</th>
<td class="pes-text-left">
<div>IV</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tropicalisation</th>
<td class="pes-text-left">
<div>2 conforming to IEC 60068-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">relative humidity</th>
<td class="pes-text-left">
<div>95 % at 55 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">operating altitude</th>
<td class="pes-text-left">
<div>0&#8230;2000 m</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for operation</th>
<td class="pes-text-left">
<div>-35…70 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for storage</th>
<td class="pes-text-left">
<div>-40…85 °C</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Packing Units</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 1</th>
<td class="pes-text-left">
<div>PCE</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 1</th>
<td class="pes-text-left">
<div>1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Weight</th>
<td class="pes-text-left">
<div>347 g</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Height</th>
<td class="pes-text-left">
<div>5.3 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 width</th>
<td class="pes-text-left">
<div>7.3 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Length</th>
<td class="pes-text-left">
<div>9.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 2</th>
<td class="pes-text-left">
<div>BB1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 2</th>
<td class="pes-text-left">
<div>4</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Weight</th>
<td class="pes-text-left">
<div>1.451 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Height</th>
<td class="pes-text-left">
<div>8.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 width</th>
<td class="pes-text-left">
<div>10 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Length</th>
<td class="pes-text-left">
<div>22.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 3</th>
<td class="pes-text-left">
<div>S03</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 3</th>
<td class="pes-text-left">
<div>44</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Weight</th>
<td class="pes-text-left">
<div>16.385 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Height</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 width</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Length</th>
<td class="pes-text-left">
<div>40 cm</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Offer Sustainability</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Sustainable offer status</th>
<td class="pes-text-left">
<div>Green Premium product</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfReach&amp;pid=13672222&amp;lang=en-us" target="" rel="noopener">REACh Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh free of SVHC</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">EU RoHS Directive</th>
<td class="pes-text-left">
<div>Compliant<br />
<a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672222&amp;lang=en-us" target="" rel="noopener">EU RoHS Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mercury free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">RoHS exemption information</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672222&amp;lang=en-us" target="" rel="noopener">Yes</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">China RoHS Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfRoHsChina&amp;pid=13672222&amp;lang=en-us" target="" rel="noopener">China RoHS declaration</a><br />
Product out of China RoHS scope. Substance declaration for your information</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Environmental Disclosure</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://download.schneider-electric.com/files?p_Doc_Ref=ENVPEP1409009EN" target="" rel="noopener">Product Environmental Profile</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">WEEE</th>
<td class="pes-text-left">
<div>The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Halogen content performance</th>
<td class="pes-text-left">
<div>Halogen free product</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Contractual warranty</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Warranty</th>
<td class="pes-text-left">
<div>18 months</div>
</td>
</tr>
</tbody>
</table>
<p></div><div id="tab-5fff0001672bd" class="lvca-tab-pane">Tel: 01206 862 062</p>
<p>Email: <a href="mailto:sales@electrogear.co.uk">sales@electrogear.co.uk</a></p>
<p>More Information <strong>CLICK HERE</strong></div></div></div>            <style type="text/css">
                                #lvca-tabs-6a52a0e6f17d9.lvca-style8 .lvca-tab-nav .lvca-tab.lvca-active a {
                    border-left-color: #004b96;
                }
                            </style>
            </div></div></div></div></div><p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-25a/">Schneider Acti9 3P D Curve 25A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Schneider Acti9 3P D Curve 20A</title>
		<link>https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-20a/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=schneider-acti9-3p-d-curve-20a</link>
		
		<dc:creator><![CDATA[electrogear-user]]></dc:creator>
		<pubDate>Tue, 24 Aug 2021 14:45:23 +0000</pubDate>
				<guid isPermaLink="false">https://electrogear.co.uk/?post_type=product&#038;p=24550</guid>

					<description><![CDATA[<p>A9F85320</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-20a/">Schneider Acti9 3P D Curve 20A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></description>
										<content:encoded><![CDATA[<div     class="vc_row wpb_row section vc_row-fluid " style=' padding-bottom:50px; text-align:left;'><div class=" full_section_inner clearfix"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div id="lvca-tabs-6a52a0e6f39eb" class="lvca-tabs lvca-vertical lvca-style8" data-mobile-width="600"><a href="#" class="lvca-tab-mobile-menu"><i class="lvca-icon-menu"></i>&nbsp;</a><div class="lvca-tab-nav"><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">OVERVIEW</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">DETAILS</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">MORE INFORMATION</span></a></div></div><div class="lvca-tab-panes"><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<h3 data-testid="descriptive-content-main-header"><b>Schneider Electric | Acti9 iC60H | Mini Circuit Breakers</b></h3>
<p>&nbsp;</p>
<p>The Acti9 series of MCBs by Schneider Electric provides excellent circuit protection particularly in combating short circuits and overload currents. These MCBs are rigorously tested by Schneider and are compliant with standards such as IEC/EN 60898 &amp; 60947-2. These types of MCBs are typically used in industrial or commercial buildings and can work extremely well in polluted environments.</p>
<p>&nbsp;</p>
<h3 data-testid="descriptive-content-main-header"><b>Features and benefits:</b></h3>
<p>&nbsp;</p>
<p>• Easy to install these consumer units, single clip on to Din Rail, compact in nature making wiring easier and simplifying your circuit system. Ergonomically designed with robust connections. IP20B terminal shutters.</p>
<p>• Schneider &#8216;VisiSafe&#8217; for safer operation and maintenance work on electrical circuits. Absolute safety of circuit protection guaranteed.</p>
<p>• Schneider &#8216;VisiTrip&#8217; for easier fault detection in the MCB outgoers. This can help reduce intervention time greatly, protecting the device before any further electrical problems occur.</div><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<table class="pes-table">
<tbody>
<tr>
<th class="pes-text-left char-table__title">Device application</th>
<td class="pes-text-left">
<div>Distribution</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">range</th>
<td class="pes-text-left">
<div>Acti 9</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">product name</th>
<td class="pes-text-left">
<div>Acti 9 iC60</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Product or component type</th>
<td class="pes-text-left">
<div>Miniature circuit-breaker</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">device short name</th>
<td class="pes-text-left">
<div>IC60H</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">poles description</th>
<td class="pes-text-left">
<div>3P</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">number of protected poles</th>
<td class="pes-text-left">
<div>3</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[In] rated current</th>
<td class="pes-text-left">
<div>20 A</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">network type</th>
<td class="pes-text-left">
<div>DC<br />
AC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">trip unit technology</th>
<td class="pes-text-left">
<div>Thermal-magnetic</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">curve code</th>
<td class="pes-text-left">
<div>D</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">breaking capacity</th>
<td class="pes-text-left">
<div>10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1<br />
42 kA Icu at 12&#8230;60 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at 380&#8230;415 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
30 kA Icu at 220&#8230;240 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
42 kA Icu at 100&#8230;133 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at &lt;= 180 V DC conforming to EN/IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">utilisation category</th>
<td class="pes-text-left">
<div>Category A conforming to EN 60947-2<br />
Category A conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">suitability for isolation</th>
<td class="pes-text-left">
<div>Yes conforming to EN 60898-1<br />
Yes conforming to EN 60947-2<br />
Yes conforming to IEC 60898-1<br />
Yes conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">standards</th>
<td class="pes-text-left">
<div>EN 60898-1<br />
EN 60947-2<br />
IEC 60947-2<br />
IEC 60898-1</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Complementary</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Network frequency</th>
<td class="pes-text-left">
<div>50/60 Hz</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">magnetic tripping limit</th>
<td class="pes-text-left">
<div>12 x In +/- 20 %</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ics] rated service breaking capacity</th>
<td class="pes-text-left">
<div>15 kA 50 % conforming to EN 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to EN 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to EN 60947-2 &#8211; 440 V AC 50/60 Hz<br />
15 kA 50 % conforming to IEC 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to IEC 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to IEC 60947-2 &#8211; 440 V AC 50/60 Hz<br />
7500 A 75 % conforming to EN 60898-1 &#8211; 400 V AC 50/60 Hz<br />
7500 A 75 % conforming to IEC 60898-1 &#8211; 400 V AC 50/60 Hz<br />
21 kA 50 % conforming to IEC 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
21 kA 50 % conforming to EN 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
15 kA 100 % conforming to IEC 60947-2 &#8211; 125&#8230;180 V DC<br />
15 kA 100 % conforming to EN 60947-2 &#8211; 125&#8230;180 V DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">limitation class</th>
<td class="pes-text-left">
<div>3 conforming to EN 60898-1<br />
3 conforming to IEC 60898-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ui] rated insulation voltage</th>
<td class="pes-text-left">
<div>500 V AC 50/60 Hz conforming to EN 60947-2<br />
500 V AC 50/60 Hz conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Uimp] rated impulse withstand voltage</th>
<td class="pes-text-left">
<div>6 kV conforming to EN 60947-2<br />
6 kV conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">contact position indicator</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Control type</th>
<td class="pes-text-left">
<div>Toggle</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">local signalling</th>
<td class="pes-text-left">
<div>Trip indicator</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting mode</th>
<td class="pes-text-left">
<div>Fixed</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting support</th>
<td class="pes-text-left">
<div>DIN rail</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">comb busbar and distribution block compatibility</th>
<td class="pes-text-left">
<div>Top or bottom: YES</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">9 mm pitches</th>
<td class="pes-text-left">
<div>6</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Height</th>
<td class="pes-text-left">
<div>85 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Width</th>
<td class="pes-text-left">
<div>54 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Depth</th>
<td class="pes-text-left">
<div>78.5 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Net weight</th>
<td class="pes-text-left">
<div>0.375 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">colour</th>
<td class="pes-text-left">
<div>White</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">mechanical durability</th>
<td class="pes-text-left">
<div>20000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">electrical durability</th>
<td class="pes-text-left">
<div>10000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">connections &#8211; terminals</th>
<td class="pes-text-left">
<div>Single terminal (top or bottom) 1…25 mm² rigid<br />
Single terminal (top or bottom) 1…16 mm² flexible</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">wire stripping length</th>
<td class="pes-text-left">
<div>14 mm for top or bottom connection</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tightening torque</th>
<td class="pes-text-left">
<div>2 N.m top or bottom</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">earth-leakage protection</th>
<td class="pes-text-left">
<div>Separate block</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Environment</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">IP degree of protection</th>
<td class="pes-text-left">
<div>IP20 conforming to IEC 60529<br />
IP20 conforming to EN 60529</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">pollution degree</th>
<td class="pes-text-left">
<div>3 conforming to EN 60947-2<br />
3 conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">overvoltage category</th>
<td class="pes-text-left">
<div>IV</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tropicalisation</th>
<td class="pes-text-left">
<div>2 conforming to IEC 60068-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">relative humidity</th>
<td class="pes-text-left">
<div>95 % at 55 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">operating altitude</th>
<td class="pes-text-left">
<div>0&#8230;2000 m</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for operation</th>
<td class="pes-text-left">
<div>-35…70 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for storage</th>
<td class="pes-text-left">
<div>-40…85 °C</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Packing Units</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 1</th>
<td class="pes-text-left">
<div>PCE</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 1</th>
<td class="pes-text-left">
<div>1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Weight</th>
<td class="pes-text-left">
<div>341.75 g</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Height</th>
<td class="pes-text-left">
<div>5.3 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 width</th>
<td class="pes-text-left">
<div>7.3 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Length</th>
<td class="pes-text-left">
<div>9.4 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 2</th>
<td class="pes-text-left">
<div>BB1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 2</th>
<td class="pes-text-left">
<div>4</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Weight</th>
<td class="pes-text-left">
<div>1.411 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Height</th>
<td class="pes-text-left">
<div>10 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 width</th>
<td class="pes-text-left">
<div>8 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Length</th>
<td class="pes-text-left">
<div>23 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 3</th>
<td class="pes-text-left">
<div>S03</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 3</th>
<td class="pes-text-left">
<div>44</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Weight</th>
<td class="pes-text-left">
<div>16.008 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Height</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 width</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Length</th>
<td class="pes-text-left">
<div>40 cm</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Offer Sustainability</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Sustainable offer status</th>
<td class="pes-text-left">
<div>Green Premium product</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfReach&amp;pid=13672220&amp;lang=en-us" target="" rel="noopener">REACh Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh free of SVHC</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">EU RoHS Directive</th>
<td class="pes-text-left">
<div>Compliant<br />
<a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672220&amp;lang=en-us" target="" rel="noopener">EU RoHS Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mercury free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">RoHS exemption information</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672220&amp;lang=en-us" target="" rel="noopener">Yes</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">China RoHS Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfRoHsChina&amp;pid=13672220&amp;lang=en-us" target="" rel="noopener">China RoHS declaration</a><br />
Product out of China RoHS scope. Substance declaration for your information</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Environmental Disclosure</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://download.schneider-electric.com/files?p_Doc_Ref=ENVPEP1409009EN" target="" rel="noopener">Product Environmental Profile</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">WEEE</th>
<td class="pes-text-left">
<div>The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Halogen content performance</th>
<td class="pes-text-left">
<div>Halogen free product</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Contractual warranty</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Warranty</th>
<td class="pes-text-left">
<div>18 months</div>
</td>
</tr>
</tbody>
</table>
<p></div><div id="tab-5fff0001672bd" class="lvca-tab-pane">Tel: 01206 862 062</p>
<p>Email: <a href="mailto:sales@electrogear.co.uk">sales@electrogear.co.uk</a></p>
<p>More Information <strong>CLICK HERE</strong></div></div></div>            <style type="text/css">
                                #lvca-tabs-6a52a0e6f39eb.lvca-style8 .lvca-tab-nav .lvca-tab.lvca-active a {
                    border-left-color: #004b96;
                }
                            </style>
            </div></div></div></div></div><p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-20a/">Schneider Acti9 3P D Curve 20A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Schneider Acti9 3P D Curve 16A</title>
		<link>https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-16a/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=schneider-acti9-3p-d-curve-16a</link>
		
		<dc:creator><![CDATA[electrogear-user]]></dc:creator>
		<pubDate>Tue, 24 Aug 2021 14:08:09 +0000</pubDate>
				<guid isPermaLink="false">https://electrogear.co.uk/?post_type=product&#038;p=24548</guid>

					<description><![CDATA[<p>A9F85316</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-16a/">Schneider Acti9 3P D Curve 16A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></description>
										<content:encoded><![CDATA[<div     class="vc_row wpb_row section vc_row-fluid " style=' padding-bottom:50px; text-align:left;'><div class=" full_section_inner clearfix"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div id="lvca-tabs-6a52a0e701515" class="lvca-tabs lvca-vertical lvca-style8" data-mobile-width="600"><a href="#" class="lvca-tab-mobile-menu"><i class="lvca-icon-menu"></i>&nbsp;</a><div class="lvca-tab-nav"><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">OVERVIEW</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">DETAILS</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">MORE INFORMATION</span></a></div></div><div class="lvca-tab-panes"><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<h3 data-testid="descriptive-content-main-header"><b>Schneider Electric | Acti9 iC60H | Mini Circuit Breakers</b></h3>
<p>&nbsp;</p>
<p>The Acti9 series of MCBs by Schneider Electric provides excellent circuit protection particularly in combating short circuits and overload currents. These MCBs are rigorously tested by Schneider and are compliant with standards such as IEC/EN 60898 &amp; 60947-2. These types of MCBs are typically used in industrial or commercial buildings and can work extremely well in polluted environments.</p>
<p>&nbsp;</p>
<h3 data-testid="descriptive-content-main-header"><b>Features and benefits:</b></h3>
<p>&nbsp;</p>
<p>• Easy to install these consumer units, single clip on to Din Rail, compact in nature making wiring easier and simplifying your circuit system. Ergonomically designed with robust connections. IP20B terminal shutters.</p>
<p>• Schneider &#8216;VisiSafe&#8217; for safer operation and maintenance work on electrical circuits. Absolute safety of circuit protection guaranteed.</p>
<p>• Schneider &#8216;VisiTrip&#8217; for easier fault detection in the MCB outgoers. This can help reduce intervention time greatly, protecting the device before any further electrical problems occur.</div><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<table class="pes-table">
<tbody>
<tr>
<th class="pes-text-left char-table__title">Device application</th>
<td class="pes-text-left">
<div>Distribution</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">range</th>
<td class="pes-text-left">
<div>Acti 9</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">product name</th>
<td class="pes-text-left">
<div>Acti 9 iC60</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Product or component type</th>
<td class="pes-text-left">
<div>Miniature circuit-breaker</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">device short name</th>
<td class="pes-text-left">
<div>IC60H</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">poles description</th>
<td class="pes-text-left">
<div>3P</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">number of protected poles</th>
<td class="pes-text-left">
<div>3</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[In] rated current</th>
<td class="pes-text-left">
<div>16 A</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">network type</th>
<td class="pes-text-left">
<div>AC<br />
DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">trip unit technology</th>
<td class="pes-text-left">
<div>Thermal-magnetic</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">curve code</th>
<td class="pes-text-left">
<div>D</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">breaking capacity</th>
<td class="pes-text-left">
<div>10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1<br />
42 kA Icu at 12&#8230;60 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at 380&#8230;415 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
30 kA Icu at 220&#8230;240 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
42 kA Icu at 100&#8230;133 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at &lt;= 180 V DC conforming to EN/IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">utilisation category</th>
<td class="pes-text-left">
<div>Category A conforming to EN 60947-2<br />
Category A conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">suitability for isolation</th>
<td class="pes-text-left">
<div>Yes conforming to EN 60898-1<br />
Yes conforming to EN 60947-2<br />
Yes conforming to IEC 60898-1<br />
Yes conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">standards</th>
<td class="pes-text-left">
<div>EN 60898-1<br />
IEC 60898-1<br />
IEC 60947-2<br />
EN 60947-2</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Complementary</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Network frequency</th>
<td class="pes-text-left">
<div>50/60 Hz</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">magnetic tripping limit</th>
<td class="pes-text-left">
<div>12 x In +/- 20 %</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ics] rated service breaking capacity</th>
<td class="pes-text-left">
<div>15 kA 50 % conforming to EN 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to EN 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to EN 60947-2 &#8211; 440 V AC 50/60 Hz<br />
15 kA 50 % conforming to IEC 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to IEC 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to IEC 60947-2 &#8211; 440 V AC 50/60 Hz<br />
7500 A 75 % conforming to EN 60898-1 &#8211; 400 V AC 50/60 Hz<br />
7500 A 75 % conforming to IEC 60898-1 &#8211; 400 V AC 50/60 Hz<br />
21 kA 50 % conforming to IEC 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
21 kA 50 % conforming to EN 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
15 kA 100 % conforming to IEC 60947-2 &#8211; 125&#8230;180 V DC<br />
15 kA 100 % conforming to EN 60947-2 &#8211; 125&#8230;180 V DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">limitation class</th>
<td class="pes-text-left">
<div>3 conforming to EN 60898-1<br />
3 conforming to IEC 60898-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ui] rated insulation voltage</th>
<td class="pes-text-left">
<div>500 V AC 50/60 Hz conforming to EN 60947-2<br />
500 V AC 50/60 Hz conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Uimp] rated impulse withstand voltage</th>
<td class="pes-text-left">
<div>6 kV conforming to EN 60947-2<br />
6 kV conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">contact position indicator</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Control type</th>
<td class="pes-text-left">
<div>Toggle</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">local signalling</th>
<td class="pes-text-left">
<div>Trip indicator</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting mode</th>
<td class="pes-text-left">
<div>Fixed</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting support</th>
<td class="pes-text-left">
<div>DIN rail</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">comb busbar and distribution block compatibility</th>
<td class="pes-text-left">
<div>Top or bottom: YES</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">9 mm pitches</th>
<td class="pes-text-left">
<div>6</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Height</th>
<td class="pes-text-left">
<div>85 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Width</th>
<td class="pes-text-left">
<div>54 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Depth</th>
<td class="pes-text-left">
<div>78.5 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Net weight</th>
<td class="pes-text-left">
<div>0.375 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">colour</th>
<td class="pes-text-left">
<div>White</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">mechanical durability</th>
<td class="pes-text-left">
<div>20000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">electrical durability</th>
<td class="pes-text-left">
<div>10000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">connections &#8211; terminals</th>
<td class="pes-text-left">
<div>Single terminal (top or bottom) 1…25 mm² rigid<br />
Single terminal (top or bottom) 1…16 mm² flexible</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">wire stripping length</th>
<td class="pes-text-left">
<div>14 mm for top or bottom connection</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tightening torque</th>
<td class="pes-text-left">
<div>2 N.m top or bottom</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">earth-leakage protection</th>
<td class="pes-text-left">
<div>Separate block</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Environment</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">IP degree of protection</th>
<td class="pes-text-left">
<div>IP20 conforming to IEC 60529<br />
IP20 conforming to EN 60529</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">pollution degree</th>
<td class="pes-text-left">
<div>3 conforming to EN 60947-2<br />
3 conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">overvoltage category</th>
<td class="pes-text-left">
<div>IV</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tropicalisation</th>
<td class="pes-text-left">
<div>2 conforming to IEC 60068-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">relative humidity</th>
<td class="pes-text-left">
<div>95 % at 55 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">operating altitude</th>
<td class="pes-text-left">
<div>0&#8230;2000 m</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for operation</th>
<td class="pes-text-left">
<div>-35…70 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for storage</th>
<td class="pes-text-left">
<div>-40…85 °C</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Packing Units</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 1</th>
<td class="pes-text-left">
<div>PCE</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 1</th>
<td class="pes-text-left">
<div>1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Weight</th>
<td class="pes-text-left">
<div>337.25 g</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Height</th>
<td class="pes-text-left">
<div>5.3 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 width</th>
<td class="pes-text-left">
<div>7.3 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Length</th>
<td class="pes-text-left">
<div>9.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 2</th>
<td class="pes-text-left">
<div>BB1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 2</th>
<td class="pes-text-left">
<div>4</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Weight</th>
<td class="pes-text-left">
<div>1.401 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Height</th>
<td class="pes-text-left">
<div>10 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 width</th>
<td class="pes-text-left">
<div>8 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Length</th>
<td class="pes-text-left">
<div>23 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 3</th>
<td class="pes-text-left">
<div>S03</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 3</th>
<td class="pes-text-left">
<div>44</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Weight</th>
<td class="pes-text-left">
<div>15.972 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Height</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 width</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Length</th>
<td class="pes-text-left">
<div>40 cm</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Offer Sustainability</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Sustainable offer status</th>
<td class="pes-text-left">
<div>Green Premium product</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfReach&amp;pid=13672218&amp;lang=en-us" target="" rel="noopener">REACh Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh free of SVHC</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">EU RoHS Directive</th>
<td class="pes-text-left">
<div>Compliant<br />
<a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672218&amp;lang=en-us" target="" rel="noopener">EU RoHS Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mercury free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">RoHS exemption information</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672218&amp;lang=en-us" target="" rel="noopener">Yes</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">China RoHS Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfRoHsChina&amp;pid=13672218&amp;lang=en-us" target="" rel="noopener">China RoHS declaration</a><br />
Product out of China RoHS scope. Substance declaration for your information</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Environmental Disclosure</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://download.schneider-electric.com/files?p_Doc_Ref=ENVPEP1409009EN" target="" rel="noopener">Product Environmental Profile</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">WEEE</th>
<td class="pes-text-left">
<div>The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Halogen content performance</th>
<td class="pes-text-left">
<div>Halogen free product</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Contractual warranty</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Warranty</th>
<td class="pes-text-left">
<div>18 months</div>
</td>
</tr>
</tbody>
</table>
<p></div><div id="tab-5fff0001672bd" class="lvca-tab-pane">Tel: 01206 862 062</p>
<p>Email: <a href="mailto:sales@electrogear.co.uk">sales@electrogear.co.uk</a></p>
<p>More Information <strong>CLICK HERE</strong></div></div></div>            <style type="text/css">
                                #lvca-tabs-6a52a0e701515.lvca-style8 .lvca-tab-nav .lvca-tab.lvca-active a {
                    border-left-color: #004b96;
                }
                            </style>
            </div></div></div></div></div><p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-16a/">Schneider Acti9 3P D Curve 16A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Schneider Acti9 3P D Curve 10A</title>
		<link>https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-10a/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=schneider-acti9-3p-d-curve-10a</link>
		
		<dc:creator><![CDATA[electrogear-user]]></dc:creator>
		<pubDate>Tue, 24 Aug 2021 13:45:29 +0000</pubDate>
				<guid isPermaLink="false">https://electrogear.co.uk/?post_type=product&#038;p=24546</guid>

					<description><![CDATA[<p>A9F85310</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-10a/">Schneider Acti9 3P D Curve 10A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></description>
										<content:encoded><![CDATA[<div     class="vc_row wpb_row section vc_row-fluid " style=' padding-bottom:50px; text-align:left;'><div class=" full_section_inner clearfix"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div id="lvca-tabs-6a52a0e703071" class="lvca-tabs lvca-vertical lvca-style8" data-mobile-width="600"><a href="#" class="lvca-tab-mobile-menu"><i class="lvca-icon-menu"></i>&nbsp;</a><div class="lvca-tab-nav"><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">OVERVIEW</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">DETAILS</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">MORE INFORMATION</span></a></div></div><div class="lvca-tab-panes"><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<h3 data-testid="descriptive-content-main-header"><b>Schneider Electric | Acti9 iC60H | Mini Circuit Breakers</b></h3>
<p>&nbsp;</p>
<p>The Acti9 series of MCBs by Schneider Electric provides excellent circuit protection particularly in combating short circuits and overload currents. These MCBs are rigorously tested by Schneider and are compliant with standards such as IEC/EN 60898 &amp; 60947-2. These types of MCBs are typically used in industrial or commercial buildings and can work extremely well in polluted environments.</p>
<p>&nbsp;</p>
<h3 data-testid="descriptive-content-main-header"><b>Features and benefits:</b></h3>
<p>&nbsp;</p>
<p>• Easy to install these consumer units, single clip on to Din Rail, compact in nature making wiring easier and simplifying your circuit system. Ergonomically designed with robust connections. IP20B terminal shutters.</p>
<p>• Schneider &#8216;VisiSafe&#8217; for safer operation and maintenance work on electrical circuits. Absolute safety of circuit protection guaranteed.</p>
<p>• Schneider &#8216;VisiTrip&#8217; for easier fault detection in the MCB outgoers. This can help reduce intervention time greatly, protecting the device before any further electrical problems occur.</div><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<table class="pes-table">
<tbody>
<tr>
<th class="pes-text-left char-table__title">Device application</th>
<td class="pes-text-left">
<div>Distribution</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">range</th>
<td class="pes-text-left">
<div>Acti 9</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">product name</th>
<td class="pes-text-left">
<div>Acti 9 iC60</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Product or component type</th>
<td class="pes-text-left">
<div>Miniature circuit-breaker</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">device short name</th>
<td class="pes-text-left">
<div>IC60H</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">poles description</th>
<td class="pes-text-left">
<div>3P</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">number of protected poles</th>
<td class="pes-text-left">
<div>3</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[In] rated current</th>
<td class="pes-text-left">
<div>10 A</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">network type</th>
<td class="pes-text-left">
<div>DC<br />
AC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">trip unit technology</th>
<td class="pes-text-left">
<div>Thermal-magnetic</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">curve code</th>
<td class="pes-text-left">
<div>D</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">breaking capacity</th>
<td class="pes-text-left">
<div>10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1<br />
42 kA Icu at 12&#8230;60 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at 380&#8230;415 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
30 kA Icu at 220&#8230;240 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
42 kA Icu at 100&#8230;133 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at &lt;= 180 V DC conforming to EN/IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">utilisation category</th>
<td class="pes-text-left">
<div>Category A conforming to EN 60947-2<br />
Category A conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">suitability for isolation</th>
<td class="pes-text-left">
<div>Yes conforming to EN 60898-1<br />
Yes conforming to EN 60947-2<br />
Yes conforming to IEC 60898-1<br />
Yes conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">standards</th>
<td class="pes-text-left">
<div>EN 60947-2<br />
EN 60898-1<br />
IEC 60947-2<br />
IEC 60898-1</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Complementary</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Network frequency</th>
<td class="pes-text-left">
<div>50/60 Hz</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">magnetic tripping limit</th>
<td class="pes-text-left">
<div>12 x In +/- 20 %</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ics] rated service breaking capacity</th>
<td class="pes-text-left">
<div>15 kA 50 % conforming to EN 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to EN 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to EN 60947-2 &#8211; 440 V AC 50/60 Hz<br />
15 kA 50 % conforming to IEC 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to IEC 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to IEC 60947-2 &#8211; 440 V AC 50/60 Hz<br />
7500 A 75 % conforming to EN 60898-1 &#8211; 400 V AC 50/60 Hz<br />
7500 A 75 % conforming to IEC 60898-1 &#8211; 400 V AC 50/60 Hz<br />
21 kA 50 % conforming to IEC 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
21 kA 50 % conforming to EN 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
15 kA 100 % conforming to IEC 60947-2 &#8211; 125&#8230;180 V DC<br />
15 kA 100 % conforming to EN 60947-2 &#8211; 125&#8230;180 V DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">limitation class</th>
<td class="pes-text-left">
<div>3 conforming to EN 60898-1<br />
3 conforming to IEC 60898-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ui] rated insulation voltage</th>
<td class="pes-text-left">
<div>500 V AC 50/60 Hz conforming to EN 60947-2<br />
500 V AC 50/60 Hz conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Uimp] rated impulse withstand voltage</th>
<td class="pes-text-left">
<div>6 kV conforming to EN 60947-2<br />
6 kV conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">contact position indicator</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Control type</th>
<td class="pes-text-left">
<div>Toggle</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">local signalling</th>
<td class="pes-text-left">
<div>Trip indicator</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting mode</th>
<td class="pes-text-left">
<div>Fixed</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting support</th>
<td class="pes-text-left">
<div>DIN rail</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">comb busbar and distribution block compatibility</th>
<td class="pes-text-left">
<div>Top or bottom: YES</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">9 mm pitches</th>
<td class="pes-text-left">
<div>6</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Height</th>
<td class="pes-text-left">
<div>85 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Width</th>
<td class="pes-text-left">
<div>54 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Depth</th>
<td class="pes-text-left">
<div>78.5 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Net weight</th>
<td class="pes-text-left">
<div>0.375 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">colour</th>
<td class="pes-text-left">
<div>White</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">mechanical durability</th>
<td class="pes-text-left">
<div>20000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">electrical durability</th>
<td class="pes-text-left">
<div>10000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">connections &#8211; terminals</th>
<td class="pes-text-left">
<div>Single terminal (top or bottom) 1…25 mm² rigid<br />
Single terminal (top or bottom) 1…16 mm² flexible</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">wire stripping length</th>
<td class="pes-text-left">
<div>14 mm for top or bottom connection</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tightening torque</th>
<td class="pes-text-left">
<div>2 N.m top or bottom</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">earth-leakage protection</th>
<td class="pes-text-left">
<div>Separate block</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Environment</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">IP degree of protection</th>
<td class="pes-text-left">
<div>IP20 conforming to IEC 60529<br />
IP20 conforming to EN 60529</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">pollution degree</th>
<td class="pes-text-left">
<div>3 conforming to EN 60947-2<br />
3 conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">overvoltage category</th>
<td class="pes-text-left">
<div>IV</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tropicalisation</th>
<td class="pes-text-left">
<div>2 conforming to IEC 60068-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">relative humidity</th>
<td class="pes-text-left">
<div>95 % at 55 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">operating altitude</th>
<td class="pes-text-left">
<div>0&#8230;2000 m</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for operation</th>
<td class="pes-text-left">
<div>-35…70 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for storage</th>
<td class="pes-text-left">
<div>-40…85 °C</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Packing Units</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 1</th>
<td class="pes-text-left">
<div>PCE</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 1</th>
<td class="pes-text-left">
<div>1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Weight</th>
<td class="pes-text-left">
<div>328 g</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Height</th>
<td class="pes-text-left">
<div>5.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 width</th>
<td class="pes-text-left">
<div>7.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Length</th>
<td class="pes-text-left">
<div>9.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 2</th>
<td class="pes-text-left">
<div>BB1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 2</th>
<td class="pes-text-left">
<div>4</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Weight</th>
<td class="pes-text-left">
<div>1.388 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Height</th>
<td class="pes-text-left">
<div>10 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 width</th>
<td class="pes-text-left">
<div>8 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Length</th>
<td class="pes-text-left">
<div>23 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 3</th>
<td class="pes-text-left">
<div>S03</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 3</th>
<td class="pes-text-left">
<div>44</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Weight</th>
<td class="pes-text-left">
<div>15.755 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Height</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 width</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Length</th>
<td class="pes-text-left">
<div>40 cm</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Offer Sustainability</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Sustainable offer status</th>
<td class="pes-text-left">
<div>Green Premium product</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfReach&amp;pid=13672214&amp;lang=en-us" target="" rel="noopener">REACh Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh free of SVHC</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">EU RoHS Directive</th>
<td class="pes-text-left">
<div>Compliant<br />
<a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672214&amp;lang=en-us" target="" rel="noopener">EU RoHS Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mercury free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">RoHS exemption information</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672214&amp;lang=en-us" target="" rel="noopener">Yes</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">China RoHS Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfRoHsChina&amp;pid=13672214&amp;lang=en-us" target="" rel="noopener">China RoHS declaration</a><br />
Product out of China RoHS scope. Substance declaration for your information</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Environmental Disclosure</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://download.schneider-electric.com/files?p_Doc_Ref=ENVPEP1409009EN" target="" rel="noopener">Product Environmental Profile</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">WEEE</th>
<td class="pes-text-left">
<div>The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Halogen content performance</th>
<td class="pes-text-left">
<div>Halogen free product</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Contractual warranty</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Warranty</th>
<td class="pes-text-left">
<div>18 months</div>
</td>
</tr>
</tbody>
</table>
<p></div><div id="tab-5fff0001672bd" class="lvca-tab-pane">Tel: 01206 862 062</p>
<p>Email: <a href="mailto:sales@electrogear.co.uk">sales@electrogear.co.uk</a></p>
<p>More Information <strong>CLICK HERE</strong></div></div></div>            <style type="text/css">
                                #lvca-tabs-6a52a0e703071.lvca-style8 .lvca-tab-nav .lvca-tab.lvca-active a {
                    border-left-color: #004b96;
                }
                            </style>
            </div></div></div></div></div><p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-10a/">Schneider Acti9 3P D Curve 10A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Schneider Acti9 3P D Curve 6A</title>
		<link>https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-6a/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=schneider-acti9-3p-d-curve-6a</link>
		
		<dc:creator><![CDATA[electrogear-user]]></dc:creator>
		<pubDate>Tue, 24 Aug 2021 13:43:08 +0000</pubDate>
				<guid isPermaLink="false">https://electrogear.co.uk/?post_type=product&#038;p=24544</guid>

					<description><![CDATA[<p>A9F85306</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-6a/">Schneider Acti9 3P D Curve 6A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></description>
										<content:encoded><![CDATA[<div     class="vc_row wpb_row section vc_row-fluid " style=' padding-bottom:50px; text-align:left;'><div class=" full_section_inner clearfix"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div id="lvca-tabs-6a52a0e704b4b" class="lvca-tabs lvca-vertical lvca-style8" data-mobile-width="600"><a href="#" class="lvca-tab-mobile-menu"><i class="lvca-icon-menu"></i>&nbsp;</a><div class="lvca-tab-nav"><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">OVERVIEW</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">DETAILS</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">MORE INFORMATION</span></a></div></div><div class="lvca-tab-panes"><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<h3 data-testid="descriptive-content-main-header"><b>Schneider Electric | Acti9 iC60H | Mini Circuit Breakers</b></h3>
<p>&nbsp;</p>
<p>The Acti9 series of MCBs by Schneider Electric provides excellent circuit protection particularly in combating short circuits and overload currents. These MCBs are rigorously tested by Schneider and are compliant with standards such as IEC/EN 60898 &amp; 60947-2. These types of MCBs are typically used in industrial or commercial buildings and can work extremely well in polluted environments.</p>
<p>&nbsp;</p>
<h3 data-testid="descriptive-content-main-header"><b>Features and benefits:</b></h3>
<p>&nbsp;</p>
<p>• Easy to install these consumer units, single clip on to Din Rail, compact in nature making wiring easier and simplifying your circuit system. Ergonomically designed with robust connections. IP20B terminal shutters.</p>
<p>• Schneider &#8216;VisiSafe&#8217; for safer operation and maintenance work on electrical circuits. Absolute safety of circuit protection guaranteed.</p>
<p>• Schneider &#8216;VisiTrip&#8217; for easier fault detection in the MCB outgoers. This can help reduce intervention time greatly, protecting the device before any further electrical problems occur.</div><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<table class="pes-table">
<tbody>
<tr>
<th class="pes-text-left char-table__title">Device application</th>
<td class="pes-text-left">
<div>Distribution</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">range</th>
<td class="pes-text-left">
<div>Acti 9</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">product name</th>
<td class="pes-text-left">
<div>Acti 9 iC60</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Product or component type</th>
<td class="pes-text-left">
<div>Miniature circuit-breaker</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">device short name</th>
<td class="pes-text-left">
<div>IC60H</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">poles description</th>
<td class="pes-text-left">
<div>3P</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">number of protected poles</th>
<td class="pes-text-left">
<div>3</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[In] rated current</th>
<td class="pes-text-left">
<div>6 A</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">network type</th>
<td class="pes-text-left">
<div>AC<br />
DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">trip unit technology</th>
<td class="pes-text-left">
<div>Thermal-magnetic</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">curve code</th>
<td class="pes-text-left">
<div>D</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">breaking capacity</th>
<td class="pes-text-left">
<div>10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1<br />
42 kA Icu at 12&#8230;60 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at 380&#8230;415 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
30 kA Icu at 220&#8230;240 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
42 kA Icu at 100&#8230;133 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
15 kA Icu at &lt;= 180 V DC conforming to EN/IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">utilisation category</th>
<td class="pes-text-left">
<div>Category A conforming to EN 60947-2<br />
Category A conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">suitability for isolation</th>
<td class="pes-text-left">
<div>Yes conforming to EN 60898-1<br />
Yes conforming to EN 60947-2<br />
Yes conforming to IEC 60898-1<br />
Yes conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">standards</th>
<td class="pes-text-left">
<div>IEC 60898-1<br />
EN 60947-2<br />
EN 60898-1<br />
IEC 60947-2</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Complementary</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Network frequency</th>
<td class="pes-text-left">
<div>50/60 Hz</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">magnetic tripping limit</th>
<td class="pes-text-left">
<div>12 x In +/- 20 %</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ics] rated service breaking capacity</th>
<td class="pes-text-left">
<div>15 kA 50 % conforming to EN 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to EN 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to EN 60947-2 &#8211; 440 V AC 50/60 Hz<br />
15 kA 50 % conforming to IEC 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
7.5 kA 50 % conforming to IEC 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
5 kA 50 % conforming to IEC 60947-2 &#8211; 440 V AC 50/60 Hz<br />
7500 A 75 % conforming to EN 60898-1 &#8211; 400 V AC 50/60 Hz<br />
7500 A 75 % conforming to IEC 60898-1 &#8211; 400 V AC 50/60 Hz<br />
21 kA 50 % conforming to IEC 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
21 kA 50 % conforming to EN 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
15 kA 100 % conforming to IEC 60947-2 &#8211; 125&#8230;180 V DC<br />
15 kA 100 % conforming to EN 60947-2 &#8211; 125&#8230;180 V DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">limitation class</th>
<td class="pes-text-left">
<div>3 conforming to EN 60898-1<br />
3 conforming to IEC 60898-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ui] rated insulation voltage</th>
<td class="pes-text-left">
<div>500 V AC 50/60 Hz conforming to EN 60947-2<br />
500 V AC 50/60 Hz conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Uimp] rated impulse withstand voltage</th>
<td class="pes-text-left">
<div>6 kV conforming to EN 60947-2<br />
6 kV conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">contact position indicator</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Control type</th>
<td class="pes-text-left">
<div>Toggle</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">local signalling</th>
<td class="pes-text-left">
<div>Trip indicator</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting mode</th>
<td class="pes-text-left">
<div>Fixed</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting support</th>
<td class="pes-text-left">
<div>DIN rail</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">comb busbar and distribution block compatibility</th>
<td class="pes-text-left">
<div>Top or bottom: YES</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">9 mm pitches</th>
<td class="pes-text-left">
<div>6</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Height</th>
<td class="pes-text-left">
<div>85 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Width</th>
<td class="pes-text-left">
<div>54 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Depth</th>
<td class="pes-text-left">
<div>78.5 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Net weight</th>
<td class="pes-text-left">
<div>0.375 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">colour</th>
<td class="pes-text-left">
<div>White</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">mechanical durability</th>
<td class="pes-text-left">
<div>20000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">electrical durability</th>
<td class="pes-text-left">
<div>10000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">connections &#8211; terminals</th>
<td class="pes-text-left">
<div>Single terminal (top or bottom) 1…25 mm² rigid<br />
Single terminal (top or bottom) 1…16 mm² flexible</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">wire stripping length</th>
<td class="pes-text-left">
<div>14 mm for top or bottom connection</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tightening torque</th>
<td class="pes-text-left">
<div>2 N.m top or bottom</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">earth-leakage protection</th>
<td class="pes-text-left">
<div>Separate block</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Environment</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">IP degree of protection</th>
<td class="pes-text-left">
<div>IP20 conforming to IEC 60529<br />
IP20 conforming to EN 60529</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">pollution degree</th>
<td class="pes-text-left">
<div>3 conforming to EN 60947-2<br />
3 conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">overvoltage category</th>
<td class="pes-text-left">
<div>IV</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tropicalisation</th>
<td class="pes-text-left">
<div>2 conforming to IEC 60068-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">relative humidity</th>
<td class="pes-text-left">
<div>95 % at 55 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">operating altitude</th>
<td class="pes-text-left">
<div>0&#8230;2000 m</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for operation</th>
<td class="pes-text-left">
<div>-35…70 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for storage</th>
<td class="pes-text-left">
<div>-40…85 °C</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Packing Units</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 1</th>
<td class="pes-text-left">
<div>PCE</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 1</th>
<td class="pes-text-left">
<div>1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Weight</th>
<td class="pes-text-left">
<div>326.7 g</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Height</th>
<td class="pes-text-left">
<div>5.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 width</th>
<td class="pes-text-left">
<div>7.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Length</th>
<td class="pes-text-left">
<div>9.5 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 2</th>
<td class="pes-text-left">
<div>BB1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 2</th>
<td class="pes-text-left">
<div>4</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Weight</th>
<td class="pes-text-left">
<div>1.35 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Height</th>
<td class="pes-text-left">
<div>10 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 width</th>
<td class="pes-text-left">
<div>8 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 2 Length</th>
<td class="pes-text-left">
<div>23 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 3</th>
<td class="pes-text-left">
<div>S03</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 3</th>
<td class="pes-text-left">
<div>44</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Weight</th>
<td class="pes-text-left">
<div>15.492 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Height</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 width</th>
<td class="pes-text-left">
<div>30 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 3 Length</th>
<td class="pes-text-left">
<div>40 cm</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Offer Sustainability</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Sustainable offer status</th>
<td class="pes-text-left">
<div>Green Premium product</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfReach&amp;pid=13672212&amp;lang=en-us" target="" rel="noopener">REACh Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh free of SVHC</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">EU RoHS Directive</th>
<td class="pes-text-left">
<div>Compliant<br />
<a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672212&amp;lang=en-us" target="" rel="noopener">EU RoHS Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mercury free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">RoHS exemption information</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672212&amp;lang=en-us" target="" rel="noopener">Yes</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">China RoHS Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfRoHsChina&amp;pid=13672212&amp;lang=en-us" target="" rel="noopener">China RoHS declaration</a><br />
Product out of China RoHS scope. Substance declaration for your information</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Environmental Disclosure</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://download.schneider-electric.com/files?p_Doc_Ref=ENVPEP1409009EN" target="" rel="noopener">Product Environmental Profile</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">WEEE</th>
<td class="pes-text-left">
<div>The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Halogen content performance</th>
<td class="pes-text-left">
<div>Halogen free product</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Contractual warranty</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Warranty</th>
<td class="pes-text-left">
<div>18 months</div>
<div></div>
</td>
</tr>
</tbody>
</table>
<p></div><div id="tab-5fff0001672bd" class="lvca-tab-pane">Tel: 01206 862 062</p>
<p>Email: <a href="mailto:sales@electrogear.co.uk">sales@electrogear.co.uk</a></p>
<p>More Information <strong>CLICK HERE</strong></div></div></div>            <style type="text/css">
                                #lvca-tabs-6a52a0e704b4b.lvca-style8 .lvca-tab-nav .lvca-tab.lvca-active a {
                    border-left-color: #004b96;
                }
                            </style>
            </div></div></div></div></div><p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-6a/">Schneider Acti9 3P D Curve 6A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Schneider Acti9 3P D Curve 4A</title>
		<link>https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-4a/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=schneider-acti9-3p-d-curve-4a</link>
		
		<dc:creator><![CDATA[electrogear-user]]></dc:creator>
		<pubDate>Tue, 24 Aug 2021 13:40:36 +0000</pubDate>
				<guid isPermaLink="false">https://electrogear.co.uk/?post_type=product&#038;p=24542</guid>

					<description><![CDATA[<p>A9F85304</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-4a/">Schneider Acti9 3P D Curve 4A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></description>
										<content:encoded><![CDATA[<div     class="vc_row wpb_row section vc_row-fluid " style=' padding-bottom:50px; text-align:left;'><div class=" full_section_inner clearfix"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div id="lvca-tabs-6a52a0e7064e5" class="lvca-tabs lvca-vertical lvca-style8" data-mobile-width="600"><a href="#" class="lvca-tab-mobile-menu"><i class="lvca-icon-menu"></i>&nbsp;</a><div class="lvca-tab-nav"><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">OVERVIEW</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">DETAILS</span></a></div><div class="lvca-tab"><a class="lvca-tab-label" href="#tab-5fff0001672bd"><span class="lvca-tab-title">MORE INFORMATION</span></a></div></div><div class="lvca-tab-panes"><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<h3 data-testid="descriptive-content-main-header"><b>Schneider Electric | Acti9 iC60H | Mini Circuit Breakers</b></h3>
<p>&nbsp;</p>
<p>The Acti9 series of MCBs by Schneider Electric provides excellent circuit protection particularly in combating short circuits and overload currents. These MCBs are rigorously tested by Schneider and are compliant with standards such as IEC/EN 60898 &amp; 60947-2. These types of MCBs are typically used in industrial or commercial buildings and can work extremely well in polluted environments.</p>
<p>&nbsp;</p>
<h3 data-testid="descriptive-content-main-header"><b>Features and benefits:</b></h3>
<p>&nbsp;</p>
<p>• Easy to install these consumer units, single clip on to Din Rail, compact in nature making wiring easier and simplifying your circuit system. Ergonomically designed with robust connections. IP20B terminal shutters.</p>
<p>• Schneider &#8216;VisiSafe&#8217; for safer operation and maintenance work on electrical circuits. Absolute safety of circuit protection guaranteed.</p>
<p>• Schneider &#8216;VisiTrip&#8217; for easier fault detection in the MCB outgoers. This can help reduce intervention time greatly, protecting the device before any further electrical problems occur.</div><div id="tab-5fff0001672bd" class="lvca-tab-pane"></p>
<table class="pes-table">
<tbody>
<tr>
<th class="pes-text-left char-table__title">Device application</th>
<td class="pes-text-left">
<div>Distribution</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">range</th>
<td class="pes-text-left">
<div>Acti 9</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">product name</th>
<td class="pes-text-left">
<div>Acti 9 iC60</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Product or component type</th>
<td class="pes-text-left">
<div>Miniature circuit-breaker</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">device short name</th>
<td class="pes-text-left">
<div>IC60H</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">poles description</th>
<td class="pes-text-left">
<div>3P</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">number of protected poles</th>
<td class="pes-text-left">
<div>3</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[In] rated current</th>
<td class="pes-text-left">
<div>4 A</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">network type</th>
<td class="pes-text-left">
<div>AC<br />
DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">trip unit technology</th>
<td class="pes-text-left">
<div>Thermal-magnetic</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">curve code</th>
<td class="pes-text-left">
<div>D</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">breaking capacity</th>
<td class="pes-text-left">
<div>10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1<br />
15 kA Icu at &lt;= 180 V DC conforming to EN/IEC 60947-2<br />
70 kA Icu at 12&#8230;60 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
70 kA Icu at 220&#8230;240 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
70 kA Icu at 100&#8230;133 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
70 kA Icu at 380&#8230;415 V AC 50/60 Hz conforming to EN/IEC 60947-2<br />
70 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">utilisation category</th>
<td class="pes-text-left">
<div>Category A conforming to EN 60947-2<br />
Category A conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">suitability for isolation</th>
<td class="pes-text-left">
<div>Yes conforming to EN 60898-1<br />
Yes conforming to EN 60947-2<br />
Yes conforming to IEC 60898-1<br />
Yes conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">standards</th>
<td class="pes-text-left">
<div>IEC 60898-1<br />
IEC 60947-2<br />
EN 60947-2<br />
EN 60898-1</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Complementary</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Network frequency</th>
<td class="pes-text-left">
<div>50/60 Hz</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">magnetic tripping limit</th>
<td class="pes-text-left">
<div>12 x In +/- 20 %</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ics] rated service breaking capacity</th>
<td class="pes-text-left">
<div>70 kA 100 % conforming to EN 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
70 kA 100 % conforming to IEC 60947-2 &#8211; 220&#8230;240 V AC 50/60 Hz<br />
70 kA 100 % conforming to EN 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
70 kA 100 % conforming to IEC 60947-2 &#8211; 380&#8230;415 V AC 50/60 Hz<br />
70 kA 100 % conforming to EN 60947-2 &#8211; 440 V AC 50/60 Hz<br />
70 kA 100 % conforming to IEC 60947-2 &#8211; 440 V AC 50/60 Hz<br />
7500 A 75 % conforming to EN 60898-1 &#8211; 400 V AC 50/60 Hz<br />
7500 A 75 % conforming to IEC 60898-1 &#8211; 400 V AC 50/60 Hz<br />
70 kA 100 % conforming to IEC 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
70 kA 100 % conforming to EN 60947-2 &#8211; 12&#8230;133 V AC 50/60 Hz<br />
15 kA 100 % conforming to IEC 60947-2 &#8211; 125&#8230;180 V DC<br />
15 kA 100 % conforming to EN 60947-2 &#8211; 125&#8230;180 V DC</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">limitation class</th>
<td class="pes-text-left">
<div>3 conforming to EN 60898-1<br />
3 conforming to IEC 60898-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Ui] rated insulation voltage</th>
<td class="pes-text-left">
<div>500 V AC 50/60 Hz conforming to EN 60947-2<br />
500 V AC 50/60 Hz conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">[Uimp] rated impulse withstand voltage</th>
<td class="pes-text-left">
<div>6 kV conforming to EN 60947-2<br />
6 kV conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">contact position indicator</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Control type</th>
<td class="pes-text-left">
<div>Toggle</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">local signalling</th>
<td class="pes-text-left">
<div>Trip indicator</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting mode</th>
<td class="pes-text-left">
<div>Fixed</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mounting support</th>
<td class="pes-text-left">
<div>DIN rail</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">comb busbar and distribution block compatibility</th>
<td class="pes-text-left">
<div>Top or bottom: YES</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">9 mm pitches</th>
<td class="pes-text-left">
<div>6</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Height</th>
<td class="pes-text-left">
<div>85 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Width</th>
<td class="pes-text-left">
<div>54 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Depth</th>
<td class="pes-text-left">
<div>78.5 mm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Net weight</th>
<td class="pes-text-left">
<div>0.375 kg</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">colour</th>
<td class="pes-text-left">
<div>White</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">mechanical durability</th>
<td class="pes-text-left">
<div>20000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">electrical durability</th>
<td class="pes-text-left">
<div>10000 cycles</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">connections &#8211; terminals</th>
<td class="pes-text-left">
<div>Single terminal (top or bottom) 1…25 mm² rigid<br />
Single terminal (top or bottom) 1…16 mm² flexible</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">wire stripping length</th>
<td class="pes-text-left">
<div>14 mm for top or bottom connection</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tightening torque</th>
<td class="pes-text-left">
<div>2 N.m top or bottom</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">earth-leakage protection</th>
<td class="pes-text-left">
<div>Separate block</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Environment</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">IP degree of protection</th>
<td class="pes-text-left">
<div>IP20 conforming to IEC 60529<br />
IP20 conforming to EN 60529</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">pollution degree</th>
<td class="pes-text-left">
<div>3 conforming to EN 60947-2<br />
3 conforming to IEC 60947-2</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">overvoltage category</th>
<td class="pes-text-left">
<div>IV</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">tropicalisation</th>
<td class="pes-text-left">
<div>2 conforming to IEC 60068-1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">relative humidity</th>
<td class="pes-text-left">
<div>95 % at 55 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">operating altitude</th>
<td class="pes-text-left">
<div>0&#8230;2000 m</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for operation</th>
<td class="pes-text-left">
<div>-35…70 °C</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Ambient air temperature for storage</th>
<td class="pes-text-left">
<div>-40…85 °C</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Packing Units</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Unit Type of Package 1</th>
<td class="pes-text-left">
<div>PCE</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Number of Units in Package 1</th>
<td class="pes-text-left">
<div>1</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Weight</th>
<td class="pes-text-left">
<div>330 g</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Height</th>
<td class="pes-text-left">
<div>6.8 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 width</th>
<td class="pes-text-left">
<div>5.2 cm</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Package 1 Length</th>
<td class="pes-text-left">
<div>8.9 cm</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Offer Sustainability</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Sustainable offer status</th>
<td class="pes-text-left">
<div>Green Premium product</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfReach&amp;pid=13672210&amp;lang=en-us" target="" rel="noopener">REACh Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">REACh free of SVHC</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">EU RoHS Directive</th>
<td class="pes-text-left">
<div>Compliant<br />
<a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672210&amp;lang=en-us" target="" rel="noopener">EU RoHS Declaration</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Mercury free</th>
<td class="pes-text-left">
<div>Yes</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">RoHS exemption information</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&amp;pid=13672210&amp;lang=en-us" target="" rel="noopener">Yes</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">China RoHS Regulation</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=exportPdfRoHsChina&amp;pid=13672210&amp;lang=en-us" target="" rel="noopener">China RoHS declaration</a><br />
Product out of China RoHS scope. Substance declaration for your information</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Environmental Disclosure</th>
<td class="pes-text-left">
<div><a class="pes-link" title="" href="https://download.schneider-electric.com/files?p_Doc_Ref=ENVPEP1409009EN" target="" rel="noopener">Product Environmental Profile</a></div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">WEEE</th>
<td class="pes-text-left">
<div>The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins</div>
</td>
<td></td>
</tr>
<tr>
<th class="pes-text-left char-table__title">Halogen content performance</th>
<td class="pes-text-left">
<div>Halogen free product</div>
</td>
<td></td>
</tr>
</tbody>
</table>
<table class="pes-table">
<caption class="pes-text-left">Contractual warranty</caption>
<tbody>
<tr>
<th class="pes-text-left char-table__title">Warranty</th>
<td class="pes-text-left">
<div>18 months</div>
</td>
</tr>
</tbody>
</table>
<p></div><div id="tab-5fff0001672bd" class="lvca-tab-pane">Tel: 01206 862 062</p>
<p>Email: <a href="mailto:sales@electrogear.co.uk">sales@electrogear.co.uk</a></p>
<p>More Information <strong>CLICK HERE</strong></div></div></div>            <style type="text/css">
                                #lvca-tabs-6a52a0e7064e5.lvca-style8 .lvca-tab-nav .lvca-tab.lvca-active a {
                    border-left-color: #004b96;
                }
                            </style>
            </div></div></div></div></div><p>The post <a href="https://electrogear.co.uk/product/schneider-acti9-3p-d-curve-4a/">Schneider Acti9 3P D Curve 4A</a> first appeared on <a href="https://electrogear.co.uk">Electrogear Ltd</a>.</p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
