Find out about our range of products:
Electrogear Products.
SEARCH

Schneider Acti9 3P C Curve 4A

A9F84304

 

 

 

 

Categories: , ,
 

Schneider Electric | Acti9 iC60H | Mini Circuit Breakers

 

The Acti9 series of MCBs by Schneider Electric provides excellent circuit protection particularly in combating short circuits and overload currents. These MCBs are rigorously tested by Schneider and are compliant with standards such as IEC/EN 60898 & 60947-2. These types of MCBs are typically used in industrial or commercial buildings and can work extremely well in polluted environments.

 

Features and benefits:

 

• Easy to install these consumer units, single clip on to Din Rail, compact in nature making wiring easier and simplifying your circuit system. Ergonomically designed with robust connections. IP20B terminal shutters.

• Schneider ‘VisiSafe’ for safer operation and maintenance work on electrical circuits. Absolute safety of circuit protection guaranteed.

• Schneider ‘VisiTrip’ for easier fault detection in the MCB outgoers. This can help reduce intervention time greatly, protecting the device before any further electrical problems occur.

Device application
Distribution
range
Acti 9
product name
Acti 9 iC60
Product or component type
Miniature circuit-breaker
device short name
IC60H
poles description
3P
number of protected poles
3
[In] rated current
4 A
network type
AC
DC
trip unit technology
Thermal-magnetic
curve code
C
breaking capacity
10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
15 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2
70 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
utilisation category
Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
suitability for isolation
Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
standards
IEC 60947-2
IEC 60898-1
EN 60947-2
EN 60898-1
quality labels
NF
Complementary
Network frequency
50/60 Hz
magnetic tripping limit
8 x In +/- 20 %
[Ics] rated service breaking capacity
70 kA 100 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
70 kA 100 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
70 kA 100 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
70 kA 100 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
7500 A 75 % conforming to EN 60898-1 – 400 V AC 50/60 Hz
7500 A 75 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
70 kA 100 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
70 kA 100 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 – 440 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
15 kA 100 % conforming to IEC 60947-2 – 125…180 V DC
15 kA 100 % conforming to EN 60947-2 – 125…180 V DC
limitation class
3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage
500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
contact position indicator
Yes
Control type
Toggle
local signalling
Trip indicator
Mounting mode
Fixed
Mounting support
DIN rail
comb busbar and distribution block compatibility
Top or bottom: YES
9 mm pitches
6
Height
85 mm
Width
54 mm
Depth
78.5 mm
Net weight
0.375 kg
colour
White
mechanical durability
20000 cycles
electrical durability
10000 cycles
connections – terminals
Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
wire stripping length
14 mm for top or bottom connection
tightening torque
2 N.m top or bottom
earth-leakage protection
Separate block
Environment
IP degree of protection
IP20 conforming to IEC 60529
IP20 conforming to EN 60529
pollution degree
3 conforming to EN 60947-2
3 conforming to IEC 60947-2
overvoltage category
IV
tropicalisation
2 conforming to IEC 60068-1
relative humidity
95 % at 55 °C
operating altitude
0…2000 m
Ambient air temperature for operation
-35…70 °C
Ambient air temperature for storage
-40…85 °C
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
332.5 g
Package 1 Height
5.3 cm
Package 1 width
7.3 cm
Package 1 Length
9.5 cm
Unit Type of Package 2
BB1
Number of Units in Package 2
4
Package 2 Weight
1.388 kg
Package 2 Height
10 cm
Package 2 width
8 cm
Package 2 Length
23 cm
Unit Type of Package 3
S03
Number of Units in Package 3
44
Package 3 Weight
15.788 kg
Package 3 Height
30 cm
Package 3 width
30 cm
Package 3 Length
40 cm
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
REACh free of SVHC
Yes
EU RoHS Directive
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Halogen content performance
Halogen free product
Contractual warranty
Warranty
18 months

Tel: 01206 862 062

Email: sales@electrogear.co.uk

More Information CLICK HERE